Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STUDCO BUILDING SYSTEMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STUDCO BUILDING SYSTEMS in 1700 BOULTER INDUSTRIAL PARKWAY, WEBSTER, NY 14580 (NAICS 331221). OSHA activity number 339086878.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Studco Building Systems — free Get an email when a new federal OSHA severe-injury report for Studco Building Systems is published. One employer, no account, unsubscribe in one click.
Site address
1700 BOULTER INDUSTRIAL PARKWAY
City
WEBSTER
State
NY
ZIP
14580
Mailing
1700 BOULTER INDUSTRIAL PARKWAY, WEBSTER, NY 14580
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
27
Ownership type
A

4 citations on file for this inspection.

1910.138 A

Serious Gravity 5 1 instance 13 exposed
Issued
Jun 4, 2013
Abate by
Jul 5, 2013
Penalty
Initial $3,780 · Current $1,400 Reduced
29 CFR 1910.138(a): The employer did not select appropriate hand protection when employees' hands were exposed to hazards such as those from severe cuts or lacerations;     a) On or about 5/28/13 on the roll forming lines; employees, wearing gloves comprised of 65% polyester and 35% cotton, are experiencing cuts and severe lacerations when moving coils of metal, loading metal into the forming machines, and handling formed metal studs; all with sharp edges.        Abatement Certification
Recent events (2)
  • — I (S) $1400
  • — Z (S) $3780

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jun 4, 2013
Abate by
Jul 5, 2013
Penalty
Initial $2,520 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   a) On or about 5//28/13 throughout the facility; Roll forming operators were involved in servicing and maintaining their equipment, such as but not limited to, gapping the rollers, changing the rollers, clearing jams in the rollers, lubricating the rollers, changing shear blades on the six roll forming equipment.    Abatement Certification
Recent events (2)
  • — I (S) $0
  • — Z (S) $2520

1910.147 C07 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 4, 2013
Abate by
Jul 5, 2013
Penalty
Initial $2,520 · Current $1,400 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:     a) On or about 5//28/13 throughout the facility; Roll forming operators were involved in servicing and maintaining their equipment, such as but not limited to gapping the rollers, changing the rollers, clearing jams in the rollers, lubricating the rollers, changing shear blades on the six roll forming equipment and had not been trained on the need to apply locks to energy isolation devices.      Abatement Certification
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2520

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 4, 2013
Abate by
Jul 5, 2013
Penalty
Initial $2,520 · Current $1,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts:    a) On or about 5/22/13 on Line #1; employees are walking past nine sets of forming rollers which are unguarded rotating wheels.  Two emergency stop buttons are located at either end of the forming roller line, which is approximately fifteen feet in length.       Abatement Certification
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2520

View Studco Building Systems's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339086878.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.