DEL VALLE, TX —
OSHA Inspection: CAPITAL CONCRETE PRODUCTS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CAPITAL CONCRETE PRODUCTS in 5264 HWY 71 EAST, DEL VALLE, TX 78617 (NAICS 327390). OSHA activity number 339087124.
Where did this inspection happen?
- Establishment
- CAPITAL CONCRETE PRODUCTS
- Site address
- 5264 HWY 71 EAST
- City
- DEL VALLE
- State
- TX
- ZIP
- 78617
- Mailing
- 5264 HWY 71 EAST, DEL VALLE, TX 78617
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 22
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.26 C02 IV
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $650.00 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(iv): Ladder(s) were not maintained in a good usable condition at all times. On or about May 24, 2013, the employee that runs the batch mixer used a warped 12-foot aluminum ladder with a broken leg to access a platform to check on batch progress, exposing the employee to a fall hazard.
Recent events (2)
- — I (S) $650
- — Z (S) $1360
1910.178 L06
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $570.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about May 24, 2013, and at times prior thereto, employees were operating forklifts without being certified by the employer, exposing other employees to the hazard of being struck by the forklift.
Recent events (2)
- — I (O) $570
- — Z (S) $1200
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $570.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about May 24, 2013, nonmetallic-sheathed cable powering four 110-volt receptacle boxes in series along the west wall of the warehouse was not protected in rigid conduit, exposing employees to an electrical hazard.
Recent events (2)
- — I (O) $570
- — Z (S) $1200
1910.303 B07 IV
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $570.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating. On or about May 24, 2013, the 110-volt Makita 9553NB portable grinder in the maintenance room had a cut on the outer sheathing of the flexible cable, which exposed the internal insulated wires, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $570
- — Z (S) $1200
1910.305 C04
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $570.00 Reduced
General-duty citation text
29 CFR 1910.305(c)(4): Faceplates for flush-mounted snap switches. Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: On or about May 24, 2013, a double light switch box located in the workshop was missing one of the switches, exposing employees to an electrical shock hazard.
Recent events (2)
- — I (O) $570
- — Z (S) $1200
1910.305 J01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: On or about May 24, 2013, a receptacle box powering an extension cord located in the center of the warehouse was missing its faceplate, exposing employees to an electrical hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $570.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about May 24, 2013, flexible cords were used as permanent wiring, exposing employees to electrical hazards. a: Two extension cords affixed in series to a pipe down the center of the warehouse were used permanently to power vibrators. b: An extension cord was cut and used as permanent wiring for a receptacle box in the workshop. The cord was plugged into the wall and affixed to the side of a work desk to power the portable grinder and an extension cord reel.
Recent events (2)
- — I (O) $570
- — Z (S) $1200
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: On or about May 24, 2013, flexible cords were affixed to a structure and used as permanent wiring, exposing employees to electrical hazards. a: Two extension cords affixed in series to a pipe down the center of the warehouse were used permanently to power vibrators. b: An extension cord was cut and used as permanent wiring for a receptacle box in the workshop. The cord was plugged into the wall and affixed to the side of a work desk to power the portable grinder and an extension cord reel.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 327390)
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
KISSIMMEE, FL—2026-07-15
LAN SE, LLC
FRANKLINTON, NC—2026-07-15
161551 - LINDSAY PRECAST, LLC
OGDEN, UT—2026-07-10
OLDCASTLE INFRASTRUCTURE, INC.
CHARDON, OH—2026-07-09
JAB SUPPLY CORPORATION
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339087124.