Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FEDIE CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FEDIE CONSTRUCTION, INC. in 9727 E. PEAKVIEW AVE. UNIT A, ENGLEWOOD, CO 80111 (NAICS 238170). OSHA activity number 339088452.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fedie Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Fedie Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9727 E. PEAKVIEW AVE. UNIT A
City
ENGLEWOOD
State
CO
ZIP
80111
Mailing
270 E. GRAVES AVE., CENTENNIAL, CO 80121
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 G04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 14, 2013
Abate by
Jul 3, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.    a)     On or about May 10, 2013, the employer, Fedie Construction, Inc., did not ensure employees, who were required to engage in siding repair operations from a pump-jack scaffolding system which lacked end-piece guardrail systems, were   protected from exposure to fall hazards of approximately 22 feet.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 14, 2013
Abate by
Jul 3, 2013
Penalty
Initial $2,800 · Current $1,500 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a)     On or about May 10, 2013, the employer, Fedie Construction, Inc., did not ensure employees, who were required to engage in siding repair operations on a 5/12 pitched, three-story roof without the use of an adequate fall protection system, were protected from exposure to fall hazards of approximately 22 feet.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339088452.