OSHA Inspection: HAR-CONN CHROME COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HAR-CONN CHROME COMPANY, INC. in 603 NEW PARK AVENUE, WEST HARTFORD, CT 06110 (NAICS 332813). OSHA activity number 339088767.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Har-Conn Chrome Company, INC. — free Get an email when a new federal OSHA severe-injury report for Har-Conn Chrome Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
603 NEW PARK AVENUE
City
WEST HARTFORD
State
CT
ZIP
06110
Mailing
P.O. BOX 330189, WEST HARTFORD, CT 06133
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
89
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 2, 2013
Abate by
Aug 19, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to crushing hazards:    On or about May 30, 2013, in Shipping/Receiving:  An employee was observed operating the Nissan 50 propane powered industrial truck without the provided seatbelt.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.23 A08

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 28, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons could accidentally walk was not guarded by either a standard railing with standard toeboard on all exposed sides, or a floor hole cover of standard strength and construction.  While the cover was not in place, the floor hole was not constantly attended by someone or protected by a removable standard railing:   On or about May 30, 2013 near the CN#3 lift station, the diamond plate floor hole cover had been removed, leaving a 14" wide x 28" wide floor opening for access to a steam line in the walkway.  The opening was not attended or protected by a standard railing, exposing employees to trip and fall hazards.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.147 C04 II B

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 28, 2013
Abate by
Nov 15, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:      On or about May 30, 2013, the employer had not developed machine-specific lockout procedures for equipment including, but not limited to blowers and rectifiers.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.303 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 28, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:   On or about May 30, 2013 at the D-1 Degreaser:  A reel drop had a damaged electrical cord which was used to power the CM Lodestar 1/2-ton hoist.  Employeees were exposed to electric shock hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 G01 II

Serious Gravity 5 2 instances 15 exposed
Issued
Jun 28, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   On or about May 30, 2013, in the following locations, the employer used the working space in front of electrical equipment for storage:  A.  Chrome Line near entrance:  At the Empire F002, a metal basket and two plastic trash barrels were blocking an array of disconnects labeled "Feed for small 3-phase," "nickel blower," and "Chrome."  B.  Silver Line near exit:  The work space in front of two 240V electrical panels was used for the storage of chemical containers, parts and a plastic tarp.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.305 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 28, 2013
Abate by
Aug 15, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   On or about May 30, 2013, on the Silver Line:  A four-outlet receptacle box mounted on the Silver Strike (Rack) #1, used to power equipment including pumps, had a broken faceplate, exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.305 G01 III

Serious Gravity 5 3 instances 10 exposed
Issued
Jun 28, 2013
Abate by
Nov 15, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:      On or about May 30, 2013, in the following locations, flexible cords were used in lieu of the fixed wiring of the building:    A.  Chrome Line, at the M-4 Metex Acid Salt M-629 Tank:  A flexible extension cord was used to power a Flo King, Model BX 1200 pump.    B. Silver Line, at the Silver Strike (Rack) #1:  A flexible extension cord was used to power a Flo King, Model BX 1200 pump.    C.  Shipping/Receiving:  The battery for a Yale pallet jack was being recharged through a flexible extension cord.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View Har-Conn Chrome Company, INC.'s full OSHA safety record →