Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JLG STRUCTURES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JLG STRUCTURES, INC. in 4331 THOUSAND OAKS, SAN ANTONIO, TX 78217 (NAICS 238110). OSHA activity number 339089328.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JLG Structures, INC. — free Get an email when a new federal OSHA severe-injury report for JLG Structures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4331 THOUSAND OAKS
City
SAN ANTONIO
State
TX
ZIP
78217
Mailing
8611 DERRINGTON RD., HOUSTON, TX 77064
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.300 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 5, 2013
Abate by
Jul 11, 2013
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.300(b)(2): Rotating or moving parts of equipment which were exposed to contact by employees or otherwise created a hazard were not guarded:  At worksite, East Side: On or about May 29, 2013, employees were exposed to a caught-in hazard from a Tsurumi A.C. Generator (Model TPG-2900H-DX) where the recoil starter cover was missing, therefore exposing the rotating engine cooling fan blades.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.404 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 5, 2013
Abate by
Jul 11, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.404(e)(1)(i): Conductors and equipment rated 600 volts, nominal, or less were not protected from overcurrent in accordance with their ability to safely conduct current:  At worksite, East side: On or about May 29, 2013, an employee was exposed to a fire hazard from a Tsurumi A.C. Generator (Model TPG-2900H-DX) which was missing the 18 Amp circuit breaker equipped by the manufacturer and was therefore lacking overcurrent protection.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600