NEWARK, NJ —
OSHA Inspection: WELCO ACETYLENE CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WELCO ACETYLENE CORP. in 321 ROANOKE AVE, NEWARK, NJ 07105 (NAICS 325120). OSHA activity number 339089831.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WELCO ACETYLENE CORP.
- Site address
- 321 ROANOKE AVE
- City
- NEWARK
- State
- NJ
- ZIP
- 07105
- Mailing
- 451 AVENUE P, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325120
- Employees
- 13
- Ownership type
- A
Citations
19 citations on file for this inspection.
1910.106 B02 VII C 3
- Issued
- Nov 27, 2013
- Penalty
- Initial $2,000 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.106(b)(2)(vii)(c)(3): Walls of the diked area were not designed to be liquid tight: a) Establishment - outdoor area - Acetone tank The containment wall for the 3500 gallon atmospheric storage tank containing acetone, a Category 1 flammable liquid, had an open drain pipe designed into the dike. violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1268
- — C (S) $2000
- — Z (S) $2000
1910.106 E02 IV D
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,000 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve: a) Establishment - cylinder charging room Employees dispensed acetone, a Category 1 flammable liquid, into compressed gas cylinders through in-plant piping with manually closing valves. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1268
- — C (S) $2000
- — Z (S) $2000
1910.106 E09 III
- Issued
- Nov 27, 2013
- Penalty
- Initial $2,000 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Establishment - cylinder charging room Paper towels with acetone were disposed in open plastic trash receptacles. Violation observed on or about 6/11/2013
Recent events (3)
- — F (S) $1268
- — C (S) $2000
- — Z (S) $2000
1910.119 D
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(d): The employer did not complete a compilation of written process safety information pertaining to the equipment in the process, the technology of the process, and the equipment in the process before conducting the process hazard analysis: a) Establishment The employer failed to compile PSI before conducting the PHA to include the required schedule for inspection, testing and servicing of equipment such as but not limited to the compressor oil, belts, and crankcase. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 D03 I B
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Process safety information pertaining to the equipment in the process did not include the piping and instrument diagrams (P&ID's): a) Establishment - compressor room The employer did not ensure that the written process safety information included all the necessary information pertaining to the equipment in the process when an existing shutoff valve between Compressors # 1,2,3, & 4 and the high pressure dryer was not represented on P&ID sheet # B09, B11, B13, & B15. b) Establishment - compressor room The employer did not ensure that written process safety information including all the necessary information pertaining to the equipment in the process in that the existing pressure gauge and valve at the bottom of the high pressure dryer system's flash arrestor for systems #1,2,3, & 4 were not represented on P&ID sheet # B09, B11, B13 & B15. c) Establishment - compressor room The employer did not ensure that written process safety information accurately reflected existing equipment in the process in that valve #X168J in high pressure dryer system #1, valve #X181J in high pressure dryer system #2, valve #X194J in high pressure dryer system #3, however these valves do not exist in the plant process. d) Establishment - fill room The employer did not ensure that the written process safety information included all the necessary information pertaining to the equipment in the process when an existing valve installed in Fill Rack #7 was not represented on P&ID sheet # B17. e) Establishment - trailer manifold The employer did not ensure that the written process safety information included all the necessary information pertaining to the equipment in the process when the fail safe position of the nitrogen emergency automatic valve was not identified on P&ID sheet # B02. Violations observed on or about 5/30/2013
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 E03 V
- Issued
- Nov 27, 2013
- Abate by
- Apr 16, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address facility siting: a) Establishment The 2007 and 2012 PHAs did not address potential acetylene vapor cloud explosion scenarios and the associated over pressure impact on an occupied wooded framed building located 25 feet from the compressor room and approximately 100 feet from acetylene trailers. Violation observed on or about 5/30/2013.
Recent events (5)
- — I $0
- — Z $21000
- — F (S) $1820
1910.119 E05
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not establish a system to assure that the recommendations were resolved in a timely manner and that the resolution was documented: a) Establishment - PHA A 2007 PHA line 1.24 action item was to update P&IDs with piping specifications. The current P&IDs do not include piping specifications. b) Establishment - PHA A 2007 PHA line 1.7 action item was to update P&ID sheet #B02 to reflect correctly PRV 113 pressure setting of 20 PSIG. The P&ID currently has PRV 113 labeled with a pressure setting of 15 PSIG. Violation observed on or about 5/30/13.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 F01
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process: a) Establishment - Rexarc Generator The employer did not write operating procedure for starting up the Rexarc Generator after a prolonged shutdown or return to service. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 F01 IV
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(iv): The employer's written operating procedures did not address requirements for the safety systems and their functions: a) Establishment The "Acetylene Operations Critical Operating Parameters" chart did not include the critical operating parameters and safety systems, including but not limited to PRVs and nitrogen emergency shutdown system, for the acetylene trailer operation b) Establishment The employer did not specify safety systems, including but not limited to PRVs and mercoid switches, and their function in operating procedures, including but not limited to, "Acetylene Compressor Start-up Procedure," "Rexarc High Pressure Dryer Operating Procedure," "Acetylene Compressor Shut-down Procedure," and/or the "Acetylene Operations Critical Operating Parameters." Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 F04
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel: a) Establishment The employer failed to implement an adequate safe work practice regarding control and accountability of outside contractors entering/exiting the facility. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 H02 I
- Issued
- Nov 27, 2013
- Abate by
- Apr 16, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(h)(2)(i): The employer, when selecting a contractor , did not obtain and evaluate information regarding the contract employer's safety performance and program: a) Establishment - contractor safety The employer did not evaluate the health and safety programs nor the performance of contractors including, but not limited to electrical, fire suppression, and maintenance contractors that worked on the covered process. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 J02
- Issued
- Nov 27, 2013
- Abate by
- Apr 16, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): The employer did not establish and implement written procedures to maintain the on-going integrity of process equipment: a) Establishment The employer did not establish and implement written procedures for inspecting process piping containing acetylene gas at pressures of 5 to 400 PSI. b) Establishment The employer did not establish and implement written procedures for inspecting, testing and changing out flash arrestors in the acetylene filling manifold. Violations observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 J04 II
- Issued
- Nov 27, 2013
- Abate by
- Apr 16, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspections and testing procedures performed on process equipment to maintain its mechanical integrity did not follow recognized and generally accepted good engineering practices (RAGAGEP): a) Establishment - process piping The employer did not follow RAGAGEP such as, but not limited to, NFPA 51A when they failed to conduct hydrostatic testing inspection as required on process piping containing acetylene at 5 to 400 PSI. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 J04 IV
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The documentation of each inspection and test that was performed on the process did not identify the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test: a) Establishment The acetylene filling process has been active since 2002, the employer failed to maintain documentation of data for inspection and testing activities conducted prior to 2012. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.119 J05
- Issued
- Nov 27, 2013
- Abate by
- Feb 13, 2014
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information on paragraph (d) of this section) before use: a) Establishment - compressor room Mercoid switches in panel were missing cover plates. Violation observed on or about 5/30/2013 b) Establishment - cylinder charging room Pigtails for small cylinders (B & MC) were used to fill cylinders with acetylene gas while the reinforcement cover was pinched and frayed. Violation observed on or about 5/30/2013 c) Establishment - cylinder charging room Employees charged compressed gas cylinders on line 2 while flash arrestor was labeled "bad". Violation observed on or about 5/30/2013 d) Establishment - compressor room Compressor 4 was in use with a vibrating acetylene line due to motor belt deficiency. Violation observed on or about 5/30/2013
Recent events (5)
- — I $0
- — Z $21000
- — F (S) $1820
1910.119 L01
- Issued
- Nov 27, 2013
- Abate by
- Jan 16, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(l)(1): The employer did not establish or implement written procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process: a) Establishment - Compressor room A 1 inch flow restrictor was installed on the recompression manifold without a management of change review. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1910.119 L05
- Issued
- Nov 27, 2013
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.119(l)(5): When a change covered by this paragraph resulted in a change in the operating procedures or practices required by paragraph (f) of this section, such procedures or practices were not updated accordingly: a) Establishment - compressor room Operating procedures were not updated after a change to the high pressure dryer manifold affected a change to the dryer condensate draining process. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1820
- — C (S) $2800
- — Z (S) $2800
1910.147 C04 I
- Issued
- Nov 27, 2013
- Abate by
- Mar 14, 2014
- Penalty
- Initial $2,000 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Establishment Employees locked out equipment, including but not limited to compressors, to conduct service/repairs without equipment specific procedures. Violation observed on or about 6/14/2013
Recent events (3)
- — F (S) $1268
- — C (S) $2000
- — Z (S) $2000
1910.178 L01 I
- Issued
- Nov 27, 2013
- Penalty
- Initial $2,000 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Establishment Employees operated fork trucks without completing operator training. Fork trucks were used to move empty and full tanks of acetylene gas. Violation observed on or about 5/30/2013.
Recent events (3)
- — F (S) $1268
- — C (S) $2000
- — Z (S) $2000
More inspections at Welco Acetylene Corp.
View Welco Acetylene Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 325120)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339089831.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.