OSHA Inspection: WXZ CONSTRUCTION, LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WXZ CONSTRUCTION, LLC. in 28300 LORAIN ROAD, NORTH OLMSTED, OH 44070 (NAICS 236220). OSHA activity number 339090516.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WXZ Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for WXZ Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
28300 LORAIN ROAD
City
NORTH OLMSTED
State
OH
ZIP
44070
Mailing
22720 FAIRVIEW CENTER DRIVE, SUITE #150, FAIRVIEW PARK, OH 44126
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
20
Ownership type
A

1 citation on file for this inspection.

1926.451 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 2, 2013
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):     On or about May 29, 2013 during construction activities to install plaster material on the outside of a building  the employer failed to ensure a metal fabricated frame scaffold erected and used by subcontractor employees was a minimum of 10 feet from an uninsulated and energized 120/208-volt power line.  The line passed through the scaffold and further along the line, would have come directly into contact with the scaffold were it not for an attached wooden board at the anticipated point of contact.
Recent events (3)
  • — F (S) $1440
  • — C (S) $2400
  • — Z (S) $2400

View WXZ Construction, LLC.'s full OSHA safety record →