OSHA Inspection: HAUSER PRINTING CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAUSER PRINTING CO., INC. in 109 RESEARCH, HARAHAN, LA 70123 (NAICS 323110). OSHA activity number 339090938.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hauser Printing CO., INC. — free Get an email when a new federal OSHA severe-injury report for Hauser Printing CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
109 RESEARCH
City
HARAHAN
State
LA
ZIP
70123
Mailing
109 RESEARCH, HARAHAN, LA 70123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
62
Ownership type
A

7 citations on file for this inspection.

1910.106 D04 I

Serious Gravity 5 1 instance 65 exposed
Issued
Aug 14, 2013
Abate by
Sep 17, 2013
Penalty
Initial $2,142 · Current $1,285 Reduced
29 CFR 1910.106(d)(4)(i): "Construction." Inside storage rooms were not constructed to meet the required fire-resistive rating for their use. Such construction did not comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system not designed and installed in an acceptable manner. Openings to other rooms or buildings were not provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area were not at least 4 inches below the surrounding floor. Openings were not provided with approved self-closing fire doors. The room was not liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp was not an open-grated trench inside of the room which drains to a safe location. Where other portions of the building or other properties are exposed, windows were not protected as set forth in the Standard for Fire Doors and Windows, NFPA No. 80-1968, which is incorporated by reference as specified in Sec. 1910.6, for Class E or F openings. Wood at least 1 inch nominal thickness was not used for shelving, racks, dunnage, scuffboards, floor overlay, and similar installations:  On or about 05/22/2013, the employer did not ensure that the ink storage room was constructed to the applicable fire protection regulations in place when the room was designated as the ink storage room. The room contains various flammable and non-flammable inks and chemicals, such as but not limited to: RD9V, D-Glazer, and Prisco Scratch Remover.
Recent events (2)
  • — I (S) $1285.2
  • — Z (S) $2142

1910.147 C04 II

Serious Gravity 5 1 instance 62 exposed
Issued
Aug 14, 2013
Abate by
Sep 3, 2013
Penalty
Initial $2,678 · Current $1,607 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about 05/22/2013, the employer did not develop specific energy control procedures for the various printing, binding, and mailing machines with electrical and kinetic energy sources, located throughout the production facility, such as but not limited to, shutting down, isolation, securing, placement and removal of Lock-out/tag-out (LOTO) devices, testing of the the equipment to ensure effectiveness of LOTO devices, etc. Specific procedures will ensure that there should be no unexpected start-up of the equipment.
Recent events (2)
  • — I (S) $1606.8
  • — Z (S) $2678

1910.147 C06 I

Serious Gravity 5 1 instance 62 exposed
Issued
Aug 14, 2013
Abate by
Sep 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about 05/22/2013, the employer did not ensure that Lock-out/Tag-out procedures that were being used were inspected and verified as adequate for the various types of printing, binding, and mailing machines, on a annual basis. Not having a annual inspection of the LOTO procedures (documented or undocumented) allows for the verification of proper procedures and the identification of improper procedures that are being used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 30 exposed
Issued
Aug 14, 2013
Abate by
Sep 3, 2013
Penalty
Initial $1,607 · Current $964 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about 05/22/2013, the employer did not ensure that circuit breakers located in Panel A in the Bindery were not marked as to their function. If unmarked breakers are shut off or turned on unexpectedly while employees are using the equipment, various injuries could occur to the employees.
Recent events (2)
  • — I (S) $964.2
  • — Z (S) $1607

1910.305 B01 II

Serious Gravity 1 1 instance 8 exposed
Issued
Aug 14, 2013
Abate by
Aug 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  On or about 05/22/2013, the employer did not ensure that open holes in Circuit Breaker Panel A located in the Bindery area were effectively closed. Circuit breakers had been removed from the panel, but were not replaced by anothr breaker or effictively closed by a plastic insert.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 4 instances 62 exposed
Issued
Aug 14, 2013
Abate by
Aug 20, 2013
Penalty
Initial $2,142 · Current $1,285 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  On or about 05/22/2013, the employer did not ensure that circuit breaker panels were not blocked to allow easy access to the panels. Circuit breaker panels at the locations below were blocked by equipment and material which would prevent employees to access the panels.  INSTANCES:      a) Circuit breaker panel behind the Heidelberg offset printing press was blocked by material placed in front of it.     b) Circuit breaker panel at gumming station blocked by large metal table positioned in front of the panel.     c) Circuit breaker panel in corner at end of gumming station blocked by material placed in front of it.      d) Circuit breaker panel at Jefferson Highway warehouse in Binding area was located behind the binding machine which requires         employees to go through and around the machine to access the panels
Recent events (2)
  • — I (S) $1285.2
  • — Z (S) $2142

1910.305 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Aug 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  On or about 05/22/2013, the employer did not ensure that flexible power cords were not protected from strain applied to the cord. A power cord from the OIO envelope Printer in the Digital Printing Dept was connected to a power strip, and due to the length of the power cord, held the power strip suspended approximately 1 ft above the floor.