PALM COAST, FL ·
OSHA Inspection: AMERICAN RADIONIC CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN RADIONIC CO., INC. in 32 HARGRONVE GRADE, PALM COAST, FL 32137 (NAICS 334414). OSHA activity number 339091274.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN RADIONIC CO., INC.
- Site address
- 32 HARGRONVE GRADE
- City
- PALM COAST
- State
- FL
- ZIP
- 32137
- Mailing
- 32 HARGRONVE GRADE, PALM COAST, FL 32137
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334414
- Employees
- 65
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.23 E01
- Issued
- Jun 25, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a. On or about May 22, 2013, the mezzanine platform next to dry line #7, did not have a mid-rail and the top rail was not 42 inches from the platform, exposing employees to a 5 feet fall hazard.
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.147 C01
- Issued
- Jun 25, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a. On or about May 22, 2013, in the winding room, the employer did not establish a program consisting of energy control procedures, employee training, and periodic inspections for employees servicing the Monostar and Polymet the machines.
Recent events (2)
- · I (S) $2450
- · Z (S) $4900
1910.212 A01
- Issued
- Jun 25, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $2,975 · Current $1,487 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about May 22, 2013, in the winding room, the Polymet used for winding material did not have a guard covering the ingoing nip points and rotating parts, exposing employees to a caught-in hazard. b. On or about May 22, 2013, in dry line #1, the Argentine Closer used to seam the cans did not have a guard covering the rotating parts of the machine, exposing employees to a caught-in hazard.
Recent events (2)
- · I (S) $1487
- · Z (S) $2975
1910.219 C04 I
- Issued
- Jun 25, 2013
- Penalty
- Initial $2,380 · Current $1,190 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a. On or about May 22, 2013, in dry line #7, the spindle shaft of the motor run test station did not have a guard on the projected end, exposing employees to a caught in hazard. b. On or about May 22, 2013, in dry line #8, the spindle shaft of the motor run test station did not have a guard on the projected end, exposing employees to a caught in hazard.
Recent events (2)
- · I (S) $1190
- · Z (S) $2380
1910.303 G02 I
- Issued
- Jun 25, 2013
- Penalty
- Initial $2,529 · Current $1,264 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a. On or about May 22, 2013, in dry line #6, the single head welder operating over 50 volts was not guarded against accidental contact, exposing employees to an electrical shock hazard.
Recent events (2)
- · I (S) $1264
- · Z (S) $2529
More inspections at American Radionic CO., INC.
View American Radionic CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334414)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339091274.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.