Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: APACHE INDUSTRIAL SERVICES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of APACHE INDUSTRIAL SERVICES in 1982 FM 2725 P.O. BOX 3000, ARANSAS PASS, TX 78335 (NAICS 238990). OSHA activity number 339092371.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apache Industrial Services — free Get an email when a new federal OSHA severe-injury report for Apache Industrial Services is published. One employer, no account, unsubscribe in one click.
Site address
1982 FM 2725 P.O. BOX 3000
City
ARANSAS PASS
State
TX
ZIP
78335
Mailing
15423 VANTAGE PKWY EAST, HOUSTON, TX 77032
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.305 G02 II

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Dec 10, 2013
Abate by
Jan 2, 2014
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:Note:  Hard service flexible cords No. 12 or larger may be spliced if the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.  At this location: Employees engaged in sandblasting activities inside a steel confined space were exposed to shock hazards from contact with an flexible energized cord used to power a portable light fixture; and whose splice was repaired with duct tape. The portable electrical cord with splices covered with duct tape was a size 16-3; with an SJO insulation type, operated at 120 volts AC, and was resting upon the steel floor of the confined space.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3000

1910.146 F03

Deleted Other-than-serious 1 instance 3 exposed
Issued
Dec 10, 2013
Abate by
Jan 2, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.146(f)(3): The entry permit that documented compliance and authorized entry to a permit space did not identify the date and the authorized duration of the entry permit:   At this location: The second half of the two-part entry permit record used daily for employees engaged in permit space sandblasting activities did not contain the date or authorized duration of the entry permit. The second half was used to verify monitoring of acceptable entry conditions taken at 15 minute intervals; as well as document the two signatures which accounted for all hazards removed from the space, and the cancellation of the confined space permit.