Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ABSOLUTE BUILDERS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ABSOLUTE BUILDERS, INC. in 612 M STREET, NW, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 339092389.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Absolute Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Absolute Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
612 M STREET, NW
City
WASHINGTON
State
DC
ZIP
20016
Mailing
3201-F 8TH STREET, NE, WASHINGTON, DC 20001
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 2 instances 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) Outside the Building, #610/612 - A foreman and carpenters were observed using extension cords which were wired into a temporary receptacle box, 110 volt 20 ampere, to power hand tools exposing them to a potential electrical shock, on or about 05/30/13.  b) Outside the Building, #610/612 -  A foreman and carpenters were observed using multiple outlet strip which was not approved for industrial use, 110 volt 20 ampere, to power hand tools exposing them to a potential electrical shock, on or about 05/30/13.  No Abatement Documentation or Certification Required
Recent events (2)
  • — I (S) $765
  • — Z (S) $1020

1926.403 I02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:  a) Outside the Building, #610/612 - A foreman and carpenters were observed using extension cords which were wired into a temporary receptacle box, 110 volt 20 ampere, to power hand tools and not protected against accidential contact exposing them to a potential electrical shock, on or about 05/30/13.  No Abatement Documentation or Certification Required
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:  a) Outside the Building, #610/612 - A foreman and carpenters were observed using extension cords which were wired into a temporary receptacle box, 110 volt 20 ampere, to power hand tools and was not provided GFCI protection exposing them to a potential electrical shock, on or about 05/30/13.  No Abatement Documentation or Certification Required
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.501 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   a) North Side of the Building, #612 - A foremen and carpenters were observed using an unguarded the ramp to enter and exit the building exposing them to a 9 foot fall onto the basement patio deck, on or about 05/30/13.  No Abatement Documentation Or Certification Required
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

View Absolute Builders, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339092389.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.