Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: C&C BULK LIQUID TRANSFER, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C&C BULK LIQUID TRANSFER, INC. in 11005 BLASIUS RD, JACKSONVILLE, FL 32218 (NAICS 484110). OSHA activity number 339093742.

Watch C&C Bulk Liquid Transfer, INC. — free Get an email when a new federal OSHA severe-injury report for C&C Bulk Liquid Transfer, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11005 BLASIUS RD
City
JACKSONVILLE
State
FL
ZIP
32218
Mailing
11005 BLASIUS RD, JACKSONVILLE, FL 32226
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484110
Employees
16
Ownership type
A

8 citations on file for this inspection.

1910.305 B02 I

Serious Gravity 5 1 instance 16 exposed
Issued
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   a. On or about May 29, 2013, in the warehouse, two outlet boxes did not have faceplate covers, exposing employees to a 110-volt electrical hazard.
Recent events (2)
  • — I (S) $1360
  • — Z (S) $1360

1910.305 B01 II

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a. On or about July 11, 2013, at the wash bay area, boiler room, under the boiler electrical control panel, an unused opening on the outlet box was not effectively closed, exposing employees to a 220-volt electrical hazard.
Recent events (2)
  • — I (S) $1360
  • — Z (S) $1360

1910.334 A02 I

Serious Gravity 5 1 instance 16 exposed
Issued
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a. On or about May 29, 2013, in the yard, two portable flexible cord sets (extension cords) were not visually inspected before use for external defects, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1360
  • — Z (S) $1360

1910.334 A02 II

Deleted Serious Gravity 5 1 instance 16 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:   a. On or about May 29, 2013, in the yard, two portable flexible cord sets (extension cords) that had defects and were not removed from service, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2040.00 · Current $0.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:   a. On or about May 29, 2013, on top of a tanker truck, an employee checking liquid levels was not protected from a 10-foot 4-inch fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2040

1910.157 C01

Other-than-serious 1 instance 16 exposed
Issued
Penalty
Initial $1360.00 · Current $0.00 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a. On or about May 29, 2013, in the warehouse, two portable fire extinguishers were blocked by stored materials, exposing employees to fire, burn and smoke inhalation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1360

1910.132 D01

Other-than-serious 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   a. On or about May 29, 2013, the employer did not assess the workplace to determine is hazards were present, or likely to be present, which necessitate the use of PPE.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L01 I

Other-than-serious 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a. On or about May, 29, 2013, employees using company forklifts were not provided with training and an evaluation of the operator's performance prior to using the forklifts.  b. On or about May, 29, 2013, employees using company jockey truck were not provided with training and an evaluation of the operator's performance prior to using the forklifts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339093742.