Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: S & S MARINE INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of S & S MARINE INC. in 4523 DUNNING ROAD, NORFOLK, VA 23518 (NAICS 336612). OSHA activity number 339093775.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S & S Marine INC. for free Get an email when a new federal OSHA severe-injury report for S & S Marine INC. is published. One employer, no account, unsubscribe in one click.
Establishment
S & S MARINE INC.
Site address
4523 DUNNING ROAD
City
NORFOLK
State
VA
ZIP
23518
Mailing
4523 DUNNING ROAD, NORFOLK, VA 23518
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
4
Ownership type
Private (A)

13 citations on file for this inspection.

1910.106 E02 III

Other-than-serious 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.106(e)(2)(iii): Drainage or other means were not provided to control spills where flammable liquids were transferred:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, employees were transferring flammable acetone and unsaturated polyester resin without the use of a means to control spills, creating a fire hazard.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1600

1910.106 E02 IV D

Other-than-serious 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jun 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the 55 gallon drums of flammable acetone and unsaturated polyester resin did not have approved self-closing valves.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.107 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,600 · Current $480 Reduced
29 CFR 1910.107(c)(3): Space-heating appliances, steam pipes, or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate.    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, an electrical baseboard heating system with some deposits of combustible residues was in the spray area, creating a fire hazard.
Recent events (2)
  • · I (S) $480
  • · Z (S) $1600

1910.107 C06

Serious 2 instances 2 exposed
Issued
Jun 14, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,600 · Current $480 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, Group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the electrical outlets in the spray area where employees were spraying flammable unsaturated polyester resin were not explosion-proof type approved for Class I, Group D locations, creating a fire hazard.    b.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the lights in the spray area where employees were spraying flammable unsaturated polyester resin were standard fluorescent lights and not explosion-proof type approved for Class I, Group D location, creating a fire hazard.
Recent events (2)
  • · I (S) $480
  • · Z (S) $1600

1910.107 E02

Other-than-serious 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees Fahrenheit (93 degrees Celsius) kept in the vicinity of spraying operation(s) exceeded the minimum required for operation:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, a 55 gallon of flammable acetone and a 55 gallon drum of flammable unsaturated polyester resin was stored in the spray area which exceeded one days use, creating a fire hazard.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1600

1910.107 E09

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,600 · Current $480 Reduced
29 CFR 1910.107(e)(9):  Flammable liquids for use in spraying operations were transferred from one container to another without both containers being effectively bonded and grounded to prevent discharge sparks of static electricity:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, employees dispensed from a 55 gallon drum of flammable acetone and a 55 gallon drum of flammable unsaturated polyester resin without the containers being effectively bonded and grounded, creating a fire hazard.
Recent events (2)
  • · I (S) $480
  • · Z (S) $1600

1910.107 G05

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.107(g)(5): The employer shall not use a cleaning solvent with a lower flashpoint than the solvents used for spray painting operations:  a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the employer was using acetone as a cleaning solvent that had a lower flashpoint than the unsaturated polyester resin and methyl ethyl ketone peroxide used for fiberglass spraying operations, creating a fire hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1600

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Sep 19, 2013
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the employer did not develop and implement a respiratory protection program for employees required to wear a negative pressure air purifying respirator while conducting fiberglass spraying operations, creating an exposure to toxic substances hazard.
Recent events (2)
  • · I (O) $0
  • · Z (S) $1200

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jun 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the employer did not provide a medical evaluation for employees required to wear a negative pressure air purifying respirator while conducting fiberglass spraying operations, creating an exposure to toxic substances hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jun 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting face piece respirators were not fit tested prior to initial use of the respirator:  a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, employees required to wear negative pressure air purifying respirators while conducting fiberglass spraying operations were not provided with a fit test prior to being required to wear the respirator, creating an exposure to toxic substances hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 K01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Sep 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii):    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the employer did not provide comprehensive training for employees required to wear negative pressure air purifying respirators, creating a lack of knowledge hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 14, 2013
Abate by
Jun 14, 2013
Penalty
Initial $1,200 · Current $360 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a.)  S & S Marine, Inc., Main Shop:  On or about 05/21/13, employees were using compressed air for cleaning purposes at over 100 p.s.i.
Recent events (2)
  • · I (S) $360
  • · Z (S) $1200

1910.303 B07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 14, 2013
Abate by
Jun 14, 2013
Penalty
Initial $1,600 · Current $480 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:    a.)  S & S Marine, Inc., Fiberglass Shop:  On or about 05/21/13, the panel box in the fiberglass shop had unused openings exposing employees to a potential arc flash hazard.