PORTLAND, TX ·
OSHA Inspection: BARNABE COLUMNA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BARNABE COLUMNA in 2220 ESCONDIDO, PORTLAND, TX 78374 (NAICS 238130). OSHA activity number 339096695.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BARNABE COLUMNA
- Site address
- 2220 ESCONDIDO
- City
- PORTLAND
- State
- TX
- ZIP
- 78374
- Mailing
- 809 10TH STREET, CORPUS CHRISTI, TX 78404
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.451 B02
- Issued
- Sep 16, 2013
- Abate by
- Oct 15, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: At this workplace employees installing windows on a two story residential exterior wall worked from a scaffold walkway less than six inches in width at the height of greater than thirteen feet.
Recent events (1)
- · Z (S) $1600
1926.451 C02
- Issued
- Sep 16, 2013
- Abate by
- Oct 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: At this workplace, employees installing windows on a residential a two story wall worked from a scaffold greater than thirteen feet in height without base plates.
Recent events (1)
- · Z (S) $0
1926.451 E01
- Issued
- Sep 16, 2013
- Abate by
- Oct 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. At this workplace, an employees installing windows on a two story exterior wall was working from a scaffold greater than thirteen feet height without a means of scaffold access.
Recent events (1)
- · Z (S) $0
1926.451 G01
- Issued
- Sep 16, 2013
- Abate by
- Oct 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: At this workplace, an employee installing windows on a residential two story exterior wall, worked from a scaffold greater thirteen feet in height without a fall protection system in place.
Recent events (1)
- · Z (S) $0
1926.451 H02 II
- Issued
- Sep 16, 2013
- Abate by
- Oct 15, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: At this workplace, employees installing windows on a residential two story exterior wall worked from a scaffold approximately thirteen feet in height without toeboards installed.
Recent events (1)
- · Z (S) $0
More inspections at Barnabe Columna
View Barnabe Columna's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339096695.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.