SAN ANTONIO, TX —
OSHA Inspection: SI PRECAST CONCRETE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SI PRECAST CONCRETE in 5111 SE LOOP 410, SAN ANTONIO, TX 78222 (NAICS 238120). OSHA activity number 339097230.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SI PRECAST CONCRETE
- Site address
- 5111 SE LOOP 410
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78222
- Mailing
- 5111 SE LOOP 410, SAN ANTONIO, TX 78222
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.178 L01 II
- Issued
- Aug 23, 2013
- Abate by
- Sep 2, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck: On or about May 30, 2013, employees were exposed to a struck-by hazard, while operating a Toyota Propane powered forklift, Model 7FGU35, in the workplace, prior to receiving training and being evaluated by their current employer.
Recent events (1)
- — Z (S) $1600
1910.212 A01
- Issued
- Aug 23, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about May 30, 2013, employees were exposed to an caught in or between hazard, while cutting wood with a Ryobi, Model TS1341, miter saw, which did not have the lower guard installed.
Recent events (1)
- — Z (S) $1600
1910.253 B02 II
- Issued
- Aug 23, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about May 30, 2013, employees were exposed to an struck-by hazard, while working in the immediate area of compressed oxygen and acetylene gas cylinders which were not secured from being knocked over.
Recent events (1)
- — Z (S) $1600
1910.253 B04 III
- Issued
- Aug 23, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: On or about May 30, 2013, employees were exposed to an struck-by hazard, while working in the immediate area of compressed oxygen and acetylene gas cylinders which were not stored separately.
Recent events (1)
- — Z (S) $1600
1910.303 G02 I
- Issued
- Aug 23, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or other means: On or about May 30, 2013, employees were exposed to an electrical hazard, while plugging an extension cord into 120VAC electrical receptacle which had approximately 8 inches of exposed live wiring between the conduit and the electrical receptacle box.
Recent events (1)
- — Z (S) $1600
1910.304 G05
- Issued
- Aug 23, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about May 30, 2013, employees were exposed to an electrical hazard, while plugging an extension cord into 120VAC electrical receptacle which was not metallically connected to the conduit to provide a continuous bond/ground.
Recent events (1)
- — Z (S) $0
1910.305 A01 I
- Issued
- Aug 23, 2013
- Abate by
- Aug 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor: On or about May 30, 2013, employees were exposed to an electrical hazard, while plugging an extension cord into 120VAC electrical receptacle which was not metallically connected to the conduit to provide a continuous bond/ground.
Recent events (1)
- — Z (S) $0
More inspections at SI Precast Concrete
View SI Precast Concrete's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339097230.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.