Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: SOTEK INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOTEK INC in 3590 JEFFERY BLVD., BLASDELL, NY 14219 (NAICS 332710). OSHA activity number 339098915.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sotek INC for free Get an email when a new federal OSHA severe-injury report for Sotek INC is published. One employer, no account, unsubscribe in one click.
Establishment
SOTEK INC
Site address
3590 JEFFERY BLVD.
City
BLASDELL
State
NY
ZIP
14219
Mailing
3590 JEFFERY BLVD., BLASDELL, NY 14219
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
75
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 15, 2013
Abate by
Aug 27, 2013
Penalty
Initial $2,975 · Current $2,231 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a) On or about 6/6/13, employer did not conduct a periodic  inspection of the energy control procedure at least annually for authroize employees.  Abatement Certification Required:
Recent events (2)
  • · I (S) $2231.25
  • · Z (S) $2975

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Jul 15, 2013
Abate by
Aug 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent.  a) On or about 6/6/13, mezzanines used as storage area did not have a plate stating the load capacity for that area.  Abatement Certification Required:
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Sotek INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339098915.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.