Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ALBERTO FRANCO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALBERTO FRANCO in 1034 S. KOSTNER AVEUNE, CHICAGO, IL 60644 (NAICS 238140). OSHA activity number 339099319.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alberto Franco for free Get an email when a new federal OSHA severe-injury report for Alberto Franco is published. One employer, no account, unsubscribe in one click.
Establishment
ALBERTO FRANCO
Site address
1034 S. KOSTNER AVEUNE
City
CHICAGO
State
IL
ZIP
60644
Mailing
5005 WEST DRUMMOND PLACE, CHICAGO, IL 60639
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

7 citations on file for this inspection.

1926.451 D03 VII

Serious Gravity 10 3 instances 3 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(d)(3)(vii): Tiebacks shall be equivalent in strength to the suspension ropes:   a) On or about May 28, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees were performing masonry activities from a two point suspended scaffold approximately fifty (50) to sixty (60) feet above the ground. The rope used to tieback the scaffold was inadequate and improperly installed, thereby exposing employees to fall hazards.   b) On or about  June 03, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees were performing masonry activities from a two point suspended scaffold approximately fifty (50) to sixty (60) feet above the ground. The wire rope used to tieback the scaffold was inadequate and improperly installed, thereby exposing employees to fall hazards.
Recent events (1)
  • · Z (S) $2800

1926.451 D16

Serious Gravity 10 3 instances 3 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(16): In addition to the normal operating brake, suspension scaffold power-operated hoists and manually operated hoists shall have a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed:    a) On or about May 28, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees were performing tuckpointing operations from a two point suspension scaffold, approximately fifty (50) feet above ground, that was not provided with a braking device or locking pawl which engages automatically following a uncontrolled movement, thereby exposing the employees to fall hazards.
Recent events (1)
  • · Z (S) $0

1926.451 D17

Serious Gravity 10 3 instances 3 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(17): Manually operated hoists shall require a positive crank force to descend:    a) On or about May 28, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees were performing tuckpointing operations from a two point suspension scaffold, approximately fifty (50) feet above ground, equipped with a manually operated hoist. The hoist did not require a positive crank force to descend, thereby exposing the employees to fall hazards.
Recent events (1)
  • · Z (S) $0

1926.501 B01

Serious Gravity 10 3 instances 10 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a) On or about May 28, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees performing masonry activities on the roofs were exposed to various fall hazards of approximately sixteen (16) to thirty (30) feet created by the presence unprotected sides and edges.
Recent events (1)
  • · Z (S) $2800

1926.501 B14

Serious Gravity 10 5 instances 10 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(14): "Wall openings." Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, shall be protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:   a) On or about May 28, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees performing masonry activities in the building were working near unprotected wall openings with fall hazards of approximately ten (10) to fifty (50) feet, thereby exposing the employees to fall hazards.   b) On or about May 28, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees performing masonry activities in the building working near unprotected interior elevator shafts/openings were exposed to fall hazards of approximately ten (10) to fifty (50) feet.
Recent events (1)
  • · Z (S) $0

1926.502 D01

Serious Gravity 10 3 instances 10 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.502(d)(1): Connectors shall be drop forged, pressed or formed steel, or made of equivalent materials:   a) On or about  June 03, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees were performing masonry activities from a two point suspended scaffold, approximately fifty (50) to sixty (60) feet above the ground.  Connectors for the personal fall arrest systems were not drop forged, pressed or formed steel, or made of equivalent materials, thereby exposing employees to fall hazards.
Recent events (1)
  • · Z (S) $2800

1926.502 D10 I

Serious Gravity 10 3 instances 10 exposed
Issued
Aug 27, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(10)(i): Except as provided in paragraph (d)(10)(ii) of this section, when vertical lifelines are used, each employee shall be attached to a separate lifeline:   a) On or about  June 03, 2013, at the jobsite located at 1034 S. Kostner Avenue, Chicago, Illinois - employees were performing masonry activities from a two point suspended scaffold approximately fifty (50) to sixty (60) feet above the ground. More than one employee was connected to the vertical lifeline, thereby exposing the employees to fall hazards.
Recent events (1)
  • · Z (S) $0