Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: ANTHONY JUNIOR'S ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANTHONY JUNIOR'S ROOFING INC. in 1094 WILLIAM FLOYD PKWY, SHIRLEY, NY 11967 (NAICS 238160). OSHA activity number 339099392.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anthony Junior'S Roofing INC. for free Get an email when a new federal OSHA severe-injury report for Anthony Junior'S Roofing INC. is published. One employer, no account, unsubscribe in one click.
Site address
1094 WILLIAM FLOYD PKWY
City
SHIRLEY
State
NY
ZIP
11967
Mailing
130 KNICKERBOCKER, BOHEMIA, NY 11716
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jun 28, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) Worksite - Employee was working under areas where objects such as, but not limited to, a ladder, power/hand tools and roofing materials could potentially fall. Employee was not provided with head protection; on, or about 06/04/13.       Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (1)
  • · Z (S) $1200

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jun 28, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.   a) Worksite, roof - Employee engaged in roof work on a residential home was observed using a pneumatic nail gun to apply roofing material. Employees were not provided eye protection; on, or about 06/04/13.        Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (1)
  • · Z (S) $1600

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 24, 2013
Abate by
Jun 28, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) Worksite, roof - Employees engaged in construction activities were observed working at the roof edge of a residential home, approximately 11 feet - 20 feet above the ground. Employees were not protected from falling, by guardrail systems, safety net systems or personal fall arrest systems; on, or about 06/04/13.        Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2800

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 24, 2013
Abate by
Jun 28, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed.  a) Worksite, roof - Employee was conducting roof work on a residential home. An A-frame ladder was laid on the roof and used in the closed position to access the higher areas; on, or about 06/04/13.       Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (1)
  • · Z (S) $2000

1926.1060 A

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 24, 2013
Abate by
Jul 5, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.  a)Worksite - Employee was conducting roof work on a residential home. An A-frame ladder was laid on the roof and used in the closed position to access the higher sections; on, or about 06/04/13.       Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19
Recent events (1)
  • · Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339099392.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.