PUEBLO, CO ·
OSHA Inspection: WASTE CONNECTIONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WASTE CONNECTIONS, INC. in 28900 E HWY 96, PUEBLO, CO 81002 (NAICS 562111). OSHA activity number 339099434.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WASTE CONNECTIONS, INC.
- Site address
- 28900 E HWY 96
- City
- PUEBLO
- State
- CO
- ZIP
- 81002
- Mailing
- 28900 E HWY 96, PUEBLO, CO 81001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Records only (C)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562111
- Employees
- 37
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.305 G02 III
- Issued
- Aug 13, 2013
- Abate by
- Aug 30, 2013
- Penalty
- Initial $2,805 · Current $2,805
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: (a) On or about May 22, 2013, and at times prior, the employer did not ensure that employees were protected from shock, burn and fire hazards in that strain relief was not provided on the hanging pendants in the repair shop: 1) the insulation was pulled back from the junction boxes of the hanging pendant for bay 1. 2) pendants in bays 1-4 were hung by the cords with no strain relief mechanism to prevent pull from damaging the cord. (b) On or about May 22, 2013, and at times prior, the employer did not ensure that employees were protected from shock, burn and fire hazards in that the insulation on each of three extension cords at the block heater plug station and one in the shed, was broken and pulled back from the plug. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- · Z (S) $2805
1904.29 B01
- Issued
- Aug 13, 2013
- Abate by
- Aug 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation: a) On or about May 22, 2013, and at times prior, the employer did not record information on the OSHA 300 log for the 2013 calendar year with the detail required in Column F in that the object/substance that directly injured or made the person ill were missing for Cases 1, 2 and 3. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- · Z (O) $0
1910.23 A08
- Issued
- Aug 13, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk was not guarded: a) On or about May 22, 2013, and at times prior, the floor hole under the electrical panels in the outbuilding was not guarded. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- · Z (O) $0
1910.303 G01
- Issued
- Aug 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) On or about May 22, 2013, and at times prior, the employer did not ensure that employees were protected from fire hazards in the outbuilding next to the fuel station in that the electrical panels were blocked from access. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- · Z (O) $0
More inspections at Waste Connections, INC.
View Waste Connections, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339099434.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.