EL PASO, TX —
OSHA Inspection: A&A PLASTERING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A&A PLASTERING in 2200 JOE BATTLE, EL PASO, TX 79936 (NAICS 238310). OSHA activity number 339100588.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A&A PLASTERING
- Site address
- 2200 JOE BATTLE
- City
- EL PASO
- State
- TX
- ZIP
- 79936
- Mailing
- 5400 SUNCREST, EL PASO, TX 79912
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 B01
- Issued
- Nov 29, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $6,160 · Current $6,160
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: On or about June 5, 2013, employer did not enusure that working scaffold was fully planked. Employee was plastering wall and being exposed to potential fall hazards exceeding 10 feet. A&A PLASTERING WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.451(b)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 313499915, CITATION NUMBER 1, ITEM NUMBER 1 AND WAS AFFIRMED AS A FINAL ORDER ON MAY 10, 2011, WITH RESPECT TO A WORKPLACE LOCATED AT 5664 N. MESA, EL PASO, TX.
Recent events (1)
- — Z (R) $6160
1926.451 F03
- Issued
- Nov 29, 2013
- Abate by
- Dec 5, 2013
- Penalty
- Initial $6,160 · Current $6,160
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about June 5, 2013, employer did not ensure that a tubular frame scaffold used for plastering operations was inspected by a competent person prior to having employees wrork from the scaffold, exposing employees to fall and struck-by hazards. A&A PlASTERING WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.451(F)(3), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER_307251827, CITATION NUMBER 1, ITEM NUMBER 2 AND WAS AFFIRMED AS A FINAL ORDER ON MAY 14, 2009, WITH RESPECT TO A WORKPLACE LOCATED AT6031 N. MESA, EL PASO, TX.
Recent events (1)
- — Z (R) $6160
More inspections at A&A Plastering