Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SANCAST, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SANCAST, INC. in 535 CLOW LANE, COSHOCTON, OH 43812 (NAICS 331511). OSHA activity number 339101206.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sancast, INC. — free Get an email when a new federal OSHA severe-injury report for Sancast, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SANCAST, INC.
Site address
535 CLOW LANE
City
COSHOCTON
State
OH
ZIP
43812
Mailing
535 CLOW LANE, COSHOCTON, OH 43812
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 50 exposed
Issued
Sep 12, 2013
Penalty
Initial $2,310 · Current $1,386 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,  a. In the production area next to the Pangborn 15 GN-4 on the north east side, the employer did not ensure the platform was guarded on all sides of the platform with standard railings. The west end of the platform did not have railings.
Recent events (2)
  • — I (S) $1386
  • — Z (S) $2310

1910.147 C07 I A

Serious Gravity 10 1 instance 50 exposed
Issued
Sep 12, 2013
Abate by
Oct 17, 2013
Penalty
Initial $5,390 · Current $3,234 Reduced
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:   29 CFR 1910.147(c)(7)(i)(A):Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  a. At the work site, the employer did not provide training to all employees, including temporary employees, that performed lockout/tagout procedures on machines such as but not limited to, the Pangborn 15 GN-4 shot blast machine.
Recent events (2)
  • — I (S) $3234
  • — Z (S) $5390

View Sancast, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339101206.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.