SHREWSBURY, MA ·
OSHA Inspection: QUBI GENERAL CONTRACTING & HOME IMPROVEMENT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUBI GENERAL CONTRACTING & HOME IMPROVEMENT in 342 MAPLE AVE, SHREWSBURY, MA 01545 (NAICS 238160). OSHA activity number 339101628.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUBI GENERAL CONTRACTING & HOME IMPROVEMENT
- Site address
- 342 MAPLE AVE
- City
- SHREWSBURY
- State
- MA
- ZIP
- 01545
- Mailing
- 130 HUNTOON MEMORIAL HWY, ROCHDALE, MA 01542
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.150 C01 VI
- Issued
- Jun 19, 2013
- Abate by
- Jun 25, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite: (a) 342 Maple Ave Shrewsbury, MA: On or about June 4, 2013, there was no fire extinguisher at this construction job site to meet the requirement set forth in this subpart when more than 5 gallons of gasoline were present.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1926.403 B02
- Issued
- Jun 19, 2013
- Abate by
- Jun 25, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and/or used in accordance with instructions included in the listing, labeling, or certification: (a) 342 Maple Ave Shrewsbury, MA: On or about June 4, 2013, a home made extension cord with a metallic quad junction box meant to be affixed to building structure was in use as a portable device, and a non construction rated RPT was observed in use, neither of which is in accordance with this subpart.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1926.451 F07
- Issued
- Jun 19, 2013
- Abate by
- Jun 25, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: (a) 342 Maple Ave Shrewsbury, MA: On or about June 4, 2013, an employee was working on a scaffold that had many safety defects and was not erected by a competent person as required by this subpart: Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1926.451 G01
- Issued
- Jun 19, 2013
- Abate by
- Jun 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: (a) 342 maple Ave Shrewsbury, MA: On or about June 4, 2013, an employee was working from a carpenters bracket scaffold that was more than 22 FT above the ground below without any fall protection as required by this subpart: Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B13
- Issued
- Jun 19, 2013
- Abate by
- Jun 25, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: (a) 342 Maple Ave Shrewsbury, MA: On or about June 4, 2013, an employee was working on this residential roof more than 25 FT above the ground below without any fall protection as required by this subpart: Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339101628.