OSHA Inspection: DELUXE BUILDING SYSTEMS INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DELUXE BUILDING SYSTEMS INC in 499 W THIRD STREET, BERWICK, PA 18603 (NAICS 321992). OSHA activity number 339101735.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deluxe Building Systems INC — free Get an email when a new federal OSHA severe-injury report for Deluxe Building Systems INC is published. One employer, no account, unsubscribe in one click.
Site address
499 W THIRD STREET
City
BERWICK
State
PA
ZIP
18603
Mailing
499 W THIRD STREET, BERWICK, PA 18603
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321992
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.29 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2013
Penalty
Initial $2,601 · Current $1,951 Reduced
29 CFR 1910.29(b)(2): Scaffold was not properly braced by cross braces and/or diagonal braces for securing vertical members together laterally. The cross braces shall be of a length that will automatically square and align vertical members so the erected scaffold is always plumb, square, and rigid.  a)  An employee used a 7 foor high, metal, mobile scaffold where the diagonal braces on the one side were missing, thereby exposing the employee to a hazard, observed 5-29-13.  CSHO observed abatement.
Recent events (2)
  • — I (S) $1950.75
  • — Z (S) $2601

1910.303 B07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 31, 2013
Penalty
Initial $2,601 · Current $1,951 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  a) Ceiling Set Area - An electrical panel box, PPL1-2B, labeled as 120v-208v 3 phase, did not have an unused circuit breaker opening covered, thereby exposing employees to the hazards associated with coming in contact with energized parts, observed 5-29-13.  CSHO observed abatement.
Recent events (2)
  • — I (S) $1950.75
  • — Z (S) $2601

View Deluxe Building Systems INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339101735.