LIVERPOOL, NY —
OSHA Inspection: A. L. GEORGE LLC DBA ONONDAGA BEVERAGE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A. L. GEORGE LLC DBA ONONDAGA BEVERAGE in 7655 EDGECOMB DRIVE, LIVERPOOL, NY 13088 (NAICS 424810). OSHA activity number 339102295.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. L. GEORGE LLC DBA ONONDAGA BEVERAGE
- Site address
- 7655 EDGECOMB DRIVE
- City
- LIVERPOOL
- State
- NY
- ZIP
- 13088
- Mailing
- 7655 EDGECOMB DRIVE, LIVERPOOL, NY 13088
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424810
- Employees
- 120
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 P01
- Issued
- Jun 21, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) Warehouse, Selection Area, on or about 6/6/13: The left strap for the LP gas container on a Nissan forklift #5 was broken and there was no locater pin for proper mounting of the gas cylinder. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1606.5
- — Z (S) $2295
1910.37 A04
- Issued
- Jun 21, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Bldg. 2, POS Area, on or about 6/6/13: Emergency lighting at the exit door was not working. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.244 A01 II
- Issued
- Jun 21, 2013
- Abate by
- Jul 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(1)(ii): Rated load(s) of portable jack(s) were not legibly and permanently marked in a prominent location on the jack(s) by casting, stamping, or other suitable means: a) Garage, on or about 6/6/13: A portable floor jack had no rated load markings on it. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jun 21, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Bldg. 2, POS Area, on or about 6/6/13: A strip outlet powering a Goldstar refrigerator and a portable drill and charger was not being used in accordance with the listing and labeling. Abatement certification must be submitted for this item.