Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: SILVERITE CONSTRUCTION COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SILVERITE CONSTRUCTION COMPANY, INC. in 721 LENOX AVE., NEW YORK, NY 10039 (NAICS 236210). OSHA activity number 339102501.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Silverite Construction Company, INC. for free Get an email when a new federal OSHA severe-injury report for Silverite Construction Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
721 LENOX AVE.
City
NEW YORK
State
NY
ZIP
10039
Mailing
520 OLD COUNTRY ROAD WEST, HICKSVILLE, NY 11802
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
230
Ownership type
Private (A)

2 citations on file for this inspection.

1926.404 B01 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 21, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,500 · Current $3,500 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.    a) 2nd floor interior, southeast corner:       An employee used an electric powered circular saw to do carpentry work. The saw was connected to an extension cord, which was routed to an electrical panel board on the 3rd floor. A ground fault circuit interrupter was not provided to the extension cord or the panel board. On or about 06/03/13.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (O) $3500
  • · Z (S) $4500

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Nov 21, 2013
Abate by
Dec 4, 2013
Penalty
Initial $4,500 · Current $3,500 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.       a) 2nd floor interior, southeast corner:       An employee used an electric powered circular saw to do carpentry work. The saw was connected to an extension cord, which was routed to an electrical panel board on the 3rd floor. The power cord of the saw and the extension cord were missing ground pins. On or about 06/03/13.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM.  FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Recent events (2)
  • · I (O) $3500
  • · Z (S) $4500

View Silverite Construction Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339102501.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.