Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTEC INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INTEC INDUSTRIES, INC. in 2024 12TH AVENUE NORTH, BIRMINGHAM, AL 35234 (NAICS 339113). OSHA activity number 339103475.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Intec Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Intec Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2024 12TH AVENUE NORTH
City
BIRMINGHAM
State
AL
ZIP
35234
Mailing
2024 12TH AVENUE NORTH, BIRMINGHAM, AL 35234
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339113
Employees
4
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Other-than-serious 1 instance 4 exposed
Issued
Aug 9, 2013
Abate by
Aug 19, 2013
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."    (a)  On or about 06/03/13 - Alternative Exit, the door designated as an alternative means of egress was not marked by a sign that read "EXIT".
Recent events (2)
  • — I (O) $510
  • — Z (S) $1020

1910.37 A03

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 9, 2013
Abate by
Aug 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  (a)  On or about 06/03/13 - Alternative Exit, the exit was blocked by several boxes of shields to be packaged and shipped.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B05

Serious Gravity 1 3 instances 4 exposed
Issued
Aug 9, 2013
Abate by
Aug 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  (a)  On or about 06/03/13 - Glue Room, the door leading to the utility room was not marked by a sign indicating that it was "Not an Exit".  (b)  On or about 06/03/13 - Glue Room, the door leading to the two storage rooms was not marked by a sign indicating that they were "Not an Exit".  (c)  On or about 06/03/13 - A door in the Snap Machine room was not marked as "Not an Exit".
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 9, 2013
Abate by
Aug 19, 2013
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by machine operation:        (a)  On or about 06/03/13 - Snap Machine #15, a cover was not provided for the foot pedal to prevent unintentional operation of the snap machine.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 9, 2013
Abate by
Aug 19, 2013
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) On or about 06/03/13 - Double-Snap machine #10, the 110-volt service cord had exposed wires.    (b) On or about 06/03/13 - Double-Snap machine #11, the 110-volt service cord had exposed wires.
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

View Intec Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339103475.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.