PATERSON, NJ —
OSHA Inspection: NORLO OF NJ LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NORLO OF NJ LLC in 132 RAILROADROAD AVE, PATERSON, NJ 07501 (NAICS 326130). OSHA activity number 339103889.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORLO OF NJ LLC
- Site address
- 132 RAILROADROAD AVE
- City
- PATERSON
- State
- NJ
- ZIP
- 07501
- Mailing
- 132 RAILROADROAD AVE, PATERSON, NJ 07501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326130
- Employees
- 4
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 C01
- Issued
- Oct 8, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a. Extrusion Lines: Employees were exposed to an 8 foot fall hazard while working from an unguarded platform that was not equipped with a guardrail system, on or about 6/06/2013.
Recent events (3)
- — F (S) $1100
- — C (S) $2000
- — Z (S) $2000
1910.101 B
- Issued
- Oct 8, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(b): Section 3.3.8, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) were stored near elevators, gang-ways or in location where heavy moving objects may strike or fall on them. a. Outside Office: A compressed oxygen gas cylinder was unsecured, free standing and stored by the office door, on or about 7/24/2013.
Recent events (3)
- — F (O) $0
- — C (S) $2800
- — Z (S) $2800
1910.253 B02 IV
- Issued
- Oct 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a. Outside Office: An oxygen compressed gas cylinder did not have a valve protection cap in-place, on or about 7/24/2013.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.110 E04 III
- Issued
- Oct 8, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: a. Throughout Facility: The index pin was missing on the Hyster and Toyota powered industrial trucks; thus allowing the cylinder to rotate during operation, on or about 6/06/2013.
Recent events (3)
- — F (O) $0
- — C (S) $2000
- — Z (S) $2000
1910.147 C01
- Issued
- Oct 8, 2013
- Abate by
- Nov 26, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a. Extrusion Lines: Employer did not establish an energy control procedure for employees performing service and maintenance on plastic extrusion machine such as but not limited to replacing connectors, motors, hoses and oils, on or about 6/06/2013.
Recent events (3)
- — F (S) $1540
- — C (S) $2800
- — Z (S) $2800
1910.178 L01 I
- Issued
- Oct 8, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. Facility: The employer did not provide training for employees operating Hyster and Toyota powered industrial trucks, on or about 6/06/2013.
Recent events (3)
- — F (S) $1100
- — C (S) $2000
- — Z (S) $2000
1910.212 A01
- Issued
- Oct 8, 2013
- Abate by
- Nov 26, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts: a. Extrusion Line # 2: An employee was exposed to an amputation hazard from the unguarded rollers of a thermoforming plastic extrusion machine. On 6/06/2013, an employee was injured by the unguarded rollers of the thermoforming plastic extrusion machine.
Recent events (3)
- — F (S) $1540
- — C (S) $2800
- — Z (S) $2800
1910.219 F03
- Issued
- Oct 8, 2013
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a. Extrusion Line # 2: An employee operating a thermoforming plastic extrusion machine was exposed to an amputation hazard from an unguarded chain, on or about 6/06/2013.
Recent events (3)
- — F (S) $1540
- — C (S) $2800
- — Z (S) $2800
1910.138 A
- Issued
- Oct 8, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. a. Extrusion Line # 2: An employee sustained third degree thermal burns to his left hand while feeding plastic through the rolls on a plastic Thermoforming machine, on or about 6/06/2013. b. Extrusion Line # 1: Employees were exposed to third degree thermal burns while performing work on plastic Thermoforming machine with a temperature of 450 degrees, on or about 7/24/2013.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
More inspections at Norlo of NJ LLC
View Norlo of NJ LLC's full OSHA safety record →
More inspections in this industry (NAICS 326130)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339103889.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.