Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: GOLIS MACHINE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GOLIS MACHINE, INC. in 92 INDUSTRIAL PARK DR, MONTROSE, PA 18801 (NAICS 332710). OSHA activity number 339106767.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Golis Machine, INC. for free Get an email when a new federal OSHA severe-injury report for Golis Machine, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GOLIS MACHINE, INC.
Site address
92 INDUSTRIAL PARK DR
City
MONTROSE
State
PA
ZIP
18801
Mailing
92 INDUSTRIAL PARK DR, MONTROSE, PA 18801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
17
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2013
Abate by
Aug 19, 2013
Penalty
Initial $2,200 · Current $1,650 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the items of this section:  a) Production Area: Specific lockout procedures were not developed and utilized for machines including the Hardinge lathe and the Tsugami mill which exposed workers to an entanglement hazard, on or about June 7, 2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $1650
  • · Z (S) $2200

1910.305 G01 IV A

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 2, 2013
Abate by
Jul 15, 2013
Penalty
Initial $2,200 · Current $1,650 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Production Area: An extension cord was used in place of permanent wiring to power a fluid pump on the Tsugami mill exposing workers to an electric shock hazard, on or about June 7, 2013.  b) Production Area: An extension cord was used in place of permanent wiring on the deburring table to power various pieces of equipment exposing workers to an electric shock hazard, on or about June 7, 2013.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $1650
  • · Z (S) $2200

View Golis Machine, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339106767.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.