MONROE, NY ·
OSHA Inspection: LGG CARPENTRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LGG CARPENTRY in 12 QUICKWAY ROAD, MONROE, NY 10950 (NAICS 238130). OSHA activity number 339112021.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LGG CARPENTRY
- Site address
- 12 QUICKWAY ROAD
- City
- MONROE
- State
- NY
- ZIP
- 10950
- Mailing
- 210 ASTOR STREET, NEWARK, NJ 07104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.451 A06
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and were not constructed and loaded in accordance with that design: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold that had not been designed by a qualified person or constructed in accordance with a safe design.
Recent events (1)
- · Z (S) $2400
1926.451 B01
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold that was not fully planked, having 1-2 planks missing.
Recent events (1)
- · Z (S) $0
1926.451 E01
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold using the cross bracing as the means of access and egress.
Recent events (1)
- · Z (S) $0
1926.451 G01
- Issued
- Aug 21, 2013
- Abate by
- Aug 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold platform 20'8" from the ground with no fall protection in place where the work was being performed.
Recent events (1)
- · Z (S) $0
1926.451 G04 IV
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold 20'8" from the ground that had no midrails installed.
Recent events (1)
- · Z (S) $0
1926.451 F03
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold that had not been inspected by a competant person at any time.
Recent events (1)
- · Z (S) $2400
1926.451 F07
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold that had not been erected by trained/experienced employees or under the supervision of a competant person.
Recent events (1)
- · Z (S) $0
1926.454 A
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold 20'8" from the ground while not having any training in the recognition of the hazards associated with the scaffold.
Recent events (1)
- · Z (S) $1600
1926.454 B
- Issued
- Aug 21, 2013
- Abate by
- Aug 31, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a) On or about April 11, 2013 and at times prior thereto at the job site; employees were working from a scaffold 20'8" from the ground that had not been erected, maintained, or inspected by a trained employee.