OSHA Inspection: THE PINES AT UTICA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE PINES AT UTICA in 1800 BUTTERFIELD AVENUE, UTICA, NY 13501 (NAICS 623110). OSHA activity number 339115636.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Pines at Utica for free Get an email when a new federal OSHA severe-injury report for The Pines at Utica is published. One employer, no account, unsubscribe in one click.
Establishment
THE PINES AT UTICA
Site address
1800 BUTTERFIELD AVENUE
City
UTICA
State
NY
ZIP
13501
Mailing
1800 BUTTERFIELD AVENUE, UTICA, NY 13501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
180
Ownership type
Private (A)

4 citations on file for this inspection.

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 27, 2013
Penalty
Initial $2,700 · Current $1,890 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision:  a. Second floor mechanical room, on or about 06/18/13:  Employee exposed to live electrical parts in that a panel box containing parts operating at 110 volts was not closed.  Abatement certification must be submitted for this item.
Recent events (2)
  • · I (S) $1890
  • · Z (S) $2700

1910.147 C04 II B

Other-than-serious 1 instance 2 exposed
Issued
Sep 27, 2013
Abate by
Oct 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  a.  Within the facility, on or about 06/13/13:  The employers lockout/tagout program did not list equipment specific procedural steps for managing hazardous energy.  Abatement certification must be submitted for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1030 C01 IV

Other-than-serious 1 instance 3 exposed
Issued
Sep 27, 2013
Abate by
Oct 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually and whenever necessary to reflect new or modified tasks and procedures which affect occupational exposure and to reflect new or reviised employee positions with occupational exposure.  A.  Within the facility, on or about 06/13/13: The exposure control plan (ECP) provided to this CSHO contmained references to the previous business, specifically Edan Park Health Services.  Additionally, portions of the plan had not been reviewed since 11/30/00.  Abatement certification must be submitted for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Sep 27, 2013
Abate by
Nov 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): 29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a.  Within the facility, on or about 06/13/13:  Employees using hazardous chemicals in the performance of their jobs.  The employer had not written nor developed a hazard communication program.  Abatement certification must be submitted for this item.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View The Pines at Utica's full OSHA safety record →