OSHA Inspection: Q. T. CONSTRUCTION COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of Q. T. CONSTRUCTION COMPANY in 4300 VETERANS BLVD., METAIRIE, LA 70006 (NAICS 238140). OSHA activity number 339115768.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Q. T. Construction Company for free Get an email when a new federal OSHA severe-injury report for Q. T. Construction Company is published. One employer, no account, unsubscribe in one click.
Site address
4300 VETERANS BLVD.
City
METAIRIE
State
LA
ZIP
70006
Mailing
3001 IOWA STREET, KENNER, LA 70065
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.403 E

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 8, 2013
Abate by
Jul 18, 2013
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.403(e): Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.      a) 4300 Veterans Blvd., Metairie, LA; On or about 6/12/13, the employer allowed employees to use an air compressor with the power cord spliced together with an extension cord. The splice was wrapped with plastic wire nuts and electrical tape that did not provide an adequate barrier to moisture.
Recent events (2)
  • · I (S) $600
  • · Z (S) $1200

1926.451 C02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 8, 2013
Abate by
Jul 18, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(c)(2)(ii): Unstable objects shall not be used to support scaffolds or platform units.      a) 4300 Veterans Blvd., Metairie, LA; On or before 6/12/13, the employer allowed an employee to work from a scaffold that was on an unstable surface. The surface was uneven dirt with objects such as rocks, broken concrete, and other debris.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000