TROY, AL ·
OSHA Inspection: TROJAN INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TROJAN INDUSTRIES, INC. in 800 HWY 231 S., TROY, AL 36081 (NAICS 336211). OSHA activity number 339117814.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TROJAN INDUSTRIES, INC.
- Site address
- 800 HWY 231 S.
- City
- TROY
- State
- AL
- ZIP
- 36081
- Mailing
- P.O. BOX 887, TROY, AL 36081
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336211
- Employees
- 18
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 26, 2013
- Abate by
- Jan 30, 2014
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were potentially exposed to crushing and struck-by hazards from a loss of load while operating an under hung cranes with below the hook lifting devices that were not subject to operational tests or periodic inspections: (a) In the mounting department: On June 11, 2013 and at times prior to; the employer failed to conduct operational tests or periodic inspections of the spreader bar attached to the JET 3 ton underhung crane exposing employees to struck-by and crushing hazards in that the below the hook lifting device was not marked with the rated weight. (b) In the metal sheet department: On June 11, 2013 and at times prior to; the employer failed to conduct operational tests or periodic inspections of the below the hook lifting device attached to the 1/2 ton underhung crane exposing employees to struck-by and crushing hazards in that the below the hook lifting device was not marked with the rated weight .
Recent events (2)
- · I (S) $2000
- · Z (S) $2800
1910.23 C01
- Issued
- Sep 26, 2013
- Abate by
- Oct 23, 2013
- Penalty
- Initial $1,020 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings: (a) The upper level working platform in the roofing area: On June 11, 2013 and at times prior to; the employer failed to provide standard railing in that the platform was missing a mid-rail, exposing employees to falls of approximately 8.5 feet.
Recent events (2)
- · I (S) $1000
- · Z (S) $1020
1910.23 D01
- Issued
- Sep 26, 2013
- Abate by
- Oct 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1): The employer did not provide standard railings or guards on stairways having four or more risers: (a) In the Roofing area: On June 11, 2013 and at times prior to; the employer failed to provide a standard guard rail for the stairs leading to the upper working platform in that the guard rail was lacking a mid-rail, exposing employees to falls of up to 5.5 feet.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C04 I
- Issued
- Sep 26, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) In the press area: On June 11, 2013 and at times prior to; the employer failed to develop procedures to control potentially hazardous energy for the Cincinnati mechanical press brake, exposing employees to amputation hazards while performing maintenance such as, but not limited to changing the clutch.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.147 C05 I
- Issued
- Sep 26, 2013
- Abate by
- Oct 4, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources: (a) In the press area: On June 11, 2013 and at times prior to; the employer failed to provide locks and tags for isolating energy of equipment such as, but not limited to the Cincinnati mechanical press, the shear press and the BEST hydraulic press, exposing employees to amputation hazards due to inadvertent energization of equipment.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.147 C06 I
- Issued
- Sep 26, 2013
- Abate by
- Oct 16, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On June 11, 2013 and at times prior to; the employer failed to conduct a periodic inspection of the energy control procedures to ensure that the requirement of this standard was being followed exposing employees to amputation hazards during maintenance operations.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.147 C07 I A
- Issued
- Sep 26, 2013
- Abate by
- Oct 16, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) On June 11, 2013 and at times prior to; The employer failed to train authorized employees on the applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, exposing employees to amputation and electrical shock hazards while conducting maintenance on the Cincinnati mechanical press, the shear press or the BEST hydraulic press.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.212 A01
- Issued
- Sep 26, 2013
- Abate by
- Oct 23, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Center floor of the shop: On June 11, 2013 and at times prior to; the employer failed to provide point of operation guarding for the shear press #17484, exposing employees to amputation hazards from the shear blade and hold downs during operation.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.212 A05
- Issued
- Sep 26, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a) On the northside/center of the facility: On June 11, 2013 and at times prior to; the employer failed to provide fan blade guards that were 1/2 inch or less, exposing employees to amputation hazards when moving/adjusting the fan.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.215 A04
- Issued
- Sep 26, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $2,040 · Current $750 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) Near the roof area: On June 11, 2013 and at times prior to; the employer failed to provide work rests for the Black and Decker, 1/2 HP bench grinder, SN 9927, operating at 3800 rpm, exposing employees to caught-in hazards when operating the machine.
Recent events (2)
- · I (S) $750
- · Z (S) $2040
1910.215 B09
- Issued
- Sep 26, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Near the roof area: On June 11, 2013 and at times prior to; the employer failed to provide a tongue guards on the right and left side that could be adjusted, on the Black and Decker bench grinder, exposing employees to struck-by hazards from a stone wheel operating at 3800 rpm.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.217 C01 I
- Issued
- Sep 26, 2013
- Abate by
- Oct 23, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): (a) In the shop, center floor: On June 11, 2013 and at times prior to; the employer failed to provide point of operation guarding for the Cincinnati mechanical press, exposing employees to amputation hazards while working from the side of the slide to position metal in the press.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.303 F02
- Issued
- Sep 26, 2013
- Abate by
- Oct 23, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) West wall of the shop: On June 11, 2013 and at times prior to; the employer failed to mark 2 electrical panels so that the purpose of the overcurrent device was evident, exposing maintenance employees amputation and electrical shock hazards during maintenance operations.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.303 G01
- Issued
- Sep 26, 2013
- Abate by
- Oct 4, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Along the east wall, center of the facility: On June 11, 2013 and at times prior to; the employer failed to provide access to an electrical panel in that it was blocked by product, exposing employees to fire hazards such as, but not limited to smoke and fume inhalation.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.305 B01 II
- Issued
- Sep 26, 2013
- Abate by
- Oct 23, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Center of facility near north wall of shop: On June 11, 2013 and at times prior to; the employer failed to close un-used openings in panel boxes, exposing employees to electrical hazards such as, but not limited to electrical arc and arc blast hazards. (b) In the shop, 30 feet southwest of item "a": On June 11, 2013 and at times prior to; the employer failed to effectively close fittings in a panel box, exposing employees to electrical arc and arc blast hazards.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.305 B02 I
- Issued
- Sep 26, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $1,700 · Current $750 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Above the electrical service panel near southwest wall: On June 11, 2013 and at times prior to; the employer failed to provide a cover for a junction box; exposing employees to hazards associated with fires, such as, but not limited to burns and smoke and fume inhalation.
Recent events (2)
- · I (S) $750
- · Z (S) $1700
1910.178 L04 III
- Issued
- Sep 26, 2013
- Abate by
- Oct 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck (PIT) operator's performance was not being conducted at least once every three years: (a) On June 11, 2013 and at times prior to; the employer failed to evaluate the performance of PIT operators exposing the operators and employees working around them to struck-by and crushing hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Trojan Industries, INC.
View Trojan Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336211)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339117814.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.