OMAHA, NE —
OSHA Inspection: CAMPESANO ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAMPESANO ROOFING in 16603 RIGGS ST., OMAHA, NE 68105 (NAICS 238160). OSHA activity number 339119513.
Where did this inspection happen?
- Establishment
- CAMPESANO ROOFING
- Site address
- 16603 RIGGS ST.
- City
- OMAHA
- State
- NE
- ZIP
- 68105
- Mailing
- 807 S. BROAD LOT 216, FREMONT, NE 68025
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of �1926.502(k) developed and implemented. 16603 Riggs St., Omaha, NE 68105 (Job-site): The employer did not ensure that adequate fall protection was provided for employees who were working on the roof of a home which was approximately 11 feet from a lower level. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: 16603 Riggs St., Omaha, NE 68105 (Job-site). The portable ladder being used by employees to access the roof did not extend at least 3 feet above the roof. Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $1600
1926.1053 B05 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and top support): 16603 Riggs St., Omaha, NE 68105 (Job-site): The portable ladder being used by employees to access the roof was not being used at an angle of approximately one-quarter the working length of the ladder. The ladder was being used at height of the top support of approximately 11 feet high and 7 feet distance between the foot and top support). Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $1600
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: 16603 Riggs St., Omaha, NE 68105 (Job-site): Employees were not trained to recognize hazards related to ladders nor trained in the procedures to be followed to minimize these hazards. Employees were using a portable ladder to access an upper landing surface. The side rails did not extend at least 3 feet above the upper landing surface and the ladder was not set up at an angle of approximately one-quarter the working length of the ladder. The ladder was being used at height of the top support of approximately 11 feet high and 7 feet distance between the foot and top support). Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NE
CRETE, NE—2026-07-15
SMITHFIELD FOODS
OMAHA, NE—2026-07-14
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339119513.