Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KILAUEA BAKERY PAU HANA PIZZA LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KILAUEA BAKERY PAU HANA PIZZA LLC in 2484 KENEKE ST., KILAUEA, HI 96754 (NAICS 311811). OSHA activity number 339121154.

Watch Kilauea Bakery PAU Hana Pizza LLC — free Get an email when a new federal OSHA severe-injury report for Kilauea Bakery PAU Hana Pizza LLC is published. One employer, no account, unsubscribe in one click.
Site address
2484 KENEKE ST.
City
KILAUEA
State
HI
ZIP
96754
Mailing
2484 KENEKE ST., KILAUEA, HI 96754
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311811
Employees
35
Ownership type
A

11 citations on file for this inspection.

1910.37 B02

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    FACILITY:  The rear exit was not marked by an Exit sign.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1910.37 B05

Other-than-serious 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    KITCHEN:  The doorway to the storage/walk ins area was not properly marked.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1400.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    KITCHEN:  The three Hobart vertical mixers, used by employees to mix, knead and whip food ingredients, were not guarded.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $3500

1910.263 C03

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1400.00 Reduced
29 CFR 1910.263(c)(3): Sprocket(s) and V-belt drive(s) of bakery machinery located within reach from platform(s) or passageway(s) or located within 8 feet 6 inches from the floor were not completely enclosed:    KITCHEN:  The sprockets on the dough sheeter, used by employees to make pizza crust, were not guarded
Recent events (2)
  • — I (S) $1400
  • — Z (S) $3500

1910.263 G02

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.263(g)(2): Handfed moulder(s) were not provided with either a belt-device or a hopper that extended high enough so that the hands of the operator could not get into the feed rolls:  KITCHEN:  The feed opening, at the top of the handfed moulder and used by employees to make pizza crust, was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 2 instances 20 exposed
Issued
Penalty
Initial $2380.00 · Current $952.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    KITCHEN:  The Relocatable Power Taps (RPT) were not used according to theirs listing and labeling.
Recent events (2)
  • — I (S) $952
  • — Z (S) $2380

1910.305 G01 IV A

Serious Gravity 5 2 instances 20 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure  KITCHEN:  The Relocatable Power Taps (RPT) and associated extension cords were used as a substitute for fixed wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 34 exposed
Issued
Penalty
Initial $2380.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    EXTERIOR STORAGE AREA:  Access to the electrical panel was not maintained.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2380

1910.304 F01 IV

Serious Gravity 5 1 instance 34 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  EXTERIOR STORAGE AREA:  Access to the electrical circuit breaker panel was blocked by equipment stored in front of it.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Other-than-serious 1 instance 34 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    EXTERIOR STORAGE AREA:  The unused openings in the electrical circuit breaker panel were not closed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  EXTERIOR STORAGE AREA:  The faceplate cover on the duplex receptacle was broken and exposed employees to live electric parts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339121154.