PEABODY, MA —
OSHA Inspection: MIGUEL LOPEZ MENDEZ
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MIGUEL LOPEZ MENDEZ in 30 CENTRAL STREET, PEABODY, MA 01960 (NAICS 238170). OSHA activity number 339121949.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MIGUEL LOPEZ MENDEZ
- Site address
- 30 CENTRAL STREET
- City
- PEABODY
- State
- MA
- ZIP
- 01960
- Mailing
- 17 HAMILTON STREET, LYNN, MA 01902
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 F06
- Issued
- Jul 3, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines were less than 10 feet. Location - 30 Central Street, Peabody, MA: On or about 06/14/2013, aluminum pump jack scaffolding systems were erected and used within the minimum approach distance for energized power lines.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1926.451 G01
- Issued
- Jul 3, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: Location - 30 Central Street, Peabody, MA: On or about 06/14/2013, the employer failed to ensure that each employee on a pump-jack scaffold was protected from falling when working at a height greater than ten feet above a lower level.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1926.452 J02
- Issued
- Jul 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. Location - 30 Central Street, Peabody, MA: On or about 06/14/2013, the employer failed to ensure that aluminum pump jack scaffolding systems were secured to the structure by rigid triangular bracing or equivalent at the bottom.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238170)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339121949.