JOLIET, IL ·
OSHA Inspection: MONROE TRUCK EQUIPMENT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of MONROE TRUCK EQUIPMENT, INC. in 812 DRAPER AVE., JOLIET, IL 60432 (NAICS 336390). OSHA activity number 339122780.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MONROE TRUCK EQUIPMENT, INC.
- Site address
- 812 DRAPER AVE.
- City
- JOLIET
- State
- IL
- ZIP
- 60432
- Mailing
- 812 DRAPER AVE., JOLIET, IL 60432
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 31
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Jul 1, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer shall establish and implement a written respiratory protection program with worksite-specific procedures. The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use: On or about June 18, 2013, in the facility, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures for employees required to use supplied-air and/or air-purifying respirators during spray finishing and sandblasting operations.
Recent events (2)
- · I (S) $1500
- · Z (S) $3000
1910.134 E01
- Issued
- Jul 1, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace: On or about June 18, 2013, in the facility, the employer did not provide a medical evaluation for employees required to wear supplied-air and/or air-purifying respirators during spray finishing and sandblasting operations.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 F02
- Issued
- Jul 1, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: On or about June 18, 2013, in the facility, the employer did not ensure that employee(s) required to wear tight-fitting facepiece respirators during spray finishing and sandblasting operations were fit tested prior to initial use of the respirator and at least annually thereafter.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 I05 IV
- Issued
- Jul 1, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer shall ensure that compressors used to supply breathing air to respirators have a tag containing the most recent in-line sorbent bed and filter change date and the signature of the person authorized by the employer to perform the change. The tag shall be maintained at the compressor: On or about June 18, 2013, in the facility, compressors used to supply breathing air to respirators worn by employees required to perform spray finishing and sandblasting operations did not have a tag containing the most recent in-line sorbent bed and filter change date and signature of authorized person.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 B05 I
- Issued
- Jul 1, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(i): In conventional dry-type spray booths, visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained: On or about June 18, 2013, in the facility, the conventional dry-type spray booth's visible guage was not in working condition.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.132 D02
- Issued
- Jul 1, 2013
- Abate by
- Aug 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment: On or about June 18, 2013, in the facility, the employer did not verify that the required workplace hazard assessment had been performed for employees required to fabricate and install truck accessories and equipment.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Monroe Truck Equipment, INC.
View Monroe Truck Equipment, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336390)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339122780.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.