PEORIA, IL ·
OSHA Inspection: ROECKERS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ROECKERS, INC. in 6523 N GALENA RD., PEORIA, IL 61615 (NAICS 337110). OSHA activity number 339124109.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROECKERS, INC.
- Site address
- 6523 N GALENA RD.
- City
- PEORIA
- State
- IL
- ZIP
- 61615
- Mailing
- 6523 N GALENA RD., PEORIA, IL 61614
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 21
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.106 E02 II B 1
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)[b][1]: The quantity of liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 25 gallons of Class I flammable liquids: Employees working within the building were exposed to fire hazards because the employer improperly stored approximately 75 gallons of class I flammable liquids in the rooms adjacent to painting operations.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.106 E02 II B 2
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(2)(ii)[b][2]: The quantity of liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons of Class 2, 3, and 4 flammable liquids: Employees working within the building were exposed to fire hazards because the employer improperly stored approximately 300 gallons of class 2, 3, and 4 flammable liquids in the rooms adjacent to painting operations.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 E01
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee�s ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Employees performing painting operations in the painting area were required to wear 3M full face respirators and the employer had not ensured that employees received medical evaluations prior to initial use of their respirators.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.134 F02
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: Employees performing painting operations in the painting area were required to wear 3M full face respirators and the employer had not ensured that employees received fit testing prior to initial use of their respirators.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 H02 I
- Issued
- Nov 26, 2013
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: An employee's respirator was found adjacent to the spray area improperly stored and was visibly contaminated with environmental contamination.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.134 K03
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: Employees performing painting operations in the painting area were required to wear 3M full face respirators and the employer had not ensured that employees received training prior to initial use of their respirators.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 L01 I
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): An employee operating the Allis-Chalmers lift had not successfully completed training and evaluation prior to operating the lift in the workplace.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.178 Q07
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: An employee was operating the Allis-Chalmers lift and the employer did not ensure the lift was examined prior to use.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Employees working around the two fans adjacent to the spray areas were exposed to electric shock and burn hazards as the electrical boxes used to wire such fans were not mounted to the building structure and used within their usage and labeling.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.303 G02 I
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): An employee working around the wooden box fan adjacent to the spray area was exposed to electric shock and burn hazards as the electrical box used to wire the fan had exposed wiring hanging out of the box.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B01 II
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: An employee working around the wooden box fan adjacent to the spray area was exposed to electric shock and burn hazards as the box was not effectively closed.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B02 I
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Employees in the break area were exposed to electrical shock and burn hazards as the electrical outlet next to the microwave did have a face cover to prevent contact with live parts. b) An employee working next to the wooden box fan adjacent to the spray area was exposed to electrical shock and burn hazards as the electrical box on the fan was missing a face cover to prevent contact with live parts.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Nov 26, 2013
- Abate by
- Dec 16, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Employees conducting painting activities were exposed to hazardous chemicals including but not limited to Sherman Williams paints and xylene and the employer did not provide training as required by the standard.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
More inspections in this industry (NAICS 337110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339124109.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.