Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VERTILUX LIMITED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VERTILUX LIMITED in 2335 NW 107TH AVENUE UNIT C-6, DORAL, FL 33172 (NAICS 313221). OSHA activity number 339124513.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vertilux Limited for free Get an email when a new federal OSHA severe-injury report for Vertilux Limited is published. One employer, no account, unsubscribe in one click.
Establishment
VERTILUX LIMITED
Site address
2335 NW 107TH AVENUE UNIT C-6
City
DORAL
State
FL
ZIP
33172
Mailing
7300 NW 35TH TERRACE, MIAMI, FL 33122
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313221
Employees
12
Ownership type
Private (A)

5 citations on file for this inspection.

1910.37 A03

Other-than-serious 1 instance 2 exposed
Issued
Aug 29, 2013
Penalty
Initial $3,600 · Current $2,124 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:     On or about June 19, 2013, at the above addressed site, employees were exposed to potentially being trapped due to an exit route not being kept free of obstructions.
Recent events (2)
  • · I (O) $2124
  • · Z (S) $3600

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 29, 2013
Penalty
Initial $3,600 · Current $3,600
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall hazard:  On or about June 19, 2013, at the above addressed site, an employee was exposed to a potential fall from being raised in a handmade wooden box supported by the forks of a Toyota forklift.
Recent events (2)
  • · I (S) $3600
  • · Z (S) $3600

1910.303 G01

Other-than-serious 1 instance 7 exposed
Issued
Aug 29, 2013
Penalty
Initial $180 · Current $180
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    On or about June 19, 2013, at the above addressed site, employees were exposed to potential electrical shock and or burns due to a wall mounted electrical panel not being provided with sufficient access while being blocked by cardboard boxes stored on a wooden pallet directly in front of that panel.    VERTILUX LIMITED WAS PREVIOSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.303(g)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 896220, CITATION NUMBER 1, ITEM NUMBER 3, AND WAS AFFIRMED AS FINAL ORDER ON 05/29/2013, WITH RESPECT TO A WORKPLACE LOCATED AT 7300 NW 35th TERRACE IN MIAMI, FLORIDA.
Recent events (2)
  • · I (O) $180
  • · Z (R) $180

1910.37 B05

Other-than-serious 2 instances 7 exposed
Issued
Aug 29, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  a) On or about June 19, 2013, at the above addressed site, employees were exposed to being trapped due to doorway in the supervisors/shipping office not being marked "Not an Exit."  b) On or about June 19, 2013, at the above addressed site, employees were exposed to being trapped due to doorway on the loading dock in the southeast corner of the warehouse not being marked "Not an Exit."
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 C04

Other-than-serious 1 instance 7 exposed
Issued
Aug 29, 2013
Abate by
Sep 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  On or about June 19, 2013, at the above addressed site, employees were exposed to potential burns due to a portable fire extinguisher not being maintained in a fully charged and operable condition.  PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Vertilux Limited's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339124513.