Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CANIDAE PET FOOD, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CANIDAE PET FOOD, INC. in 3101 STEPHEN F. AUSTIN DR., BROWNWOOD, TX 76801 (NAICS 311111). OSHA activity number 339125023.

Watch Canidae PET Food, INC. — free Get an email when a new federal OSHA severe-injury report for Canidae PET Food, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3101 STEPHEN F. AUSTIN DR.
City
BROWNWOOD
State
TX
ZIP
76801
Mailing
3101 STEPHEN F. AUSTIN DR., BROWNWOOD, TX 76801
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311111
Employees
19
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4900.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.     On or about June 14, 2013, and at times prior thereto, the employer did not develop or implement written lockout/tagout procedures for each type of equipment or machine located within the plant.  Employees performing maintenance work on the equipment such as, but not limited to the Cozzini Horizontal Screw Loader were exposed to electrical shock, caught-between and struck-by hazards.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 C07 I

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4900.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:     On or about June 14, 2013, and at times prior thereto, the employer did not train all authorized and affected employees in the recognition of all energy sources, the purpose and use of a lockout/tagout system and the general knowledge about the hazards of unexpected release of energy. Employees performing maintenance work on the equipment such as, but not limited to the Cozzini Horizontal Screw Loader were exposed to electrical shock, caught-between and struck-by hazards.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339125023.