OSHA Inspection: EMC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EMC, INC. in 3506 N. CLARK ST., CHICAGO, IL 60657 (NAICS 236220). OSHA activity number 339126203.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EMC, INC. for free Get an email when a new federal OSHA severe-injury report for EMC, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EMC, INC.
Site address
3506 N. CLARK ST.
City
CHICAGO
State
IL
ZIP
60657
Mailing
3203 S. EMERALD AVE., CHICAGO, IL 60616
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
11
Ownership type
Private (A)

6 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 1, 2013
Abate by
Aug 13, 2013
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection:  a) On or about June 19, 2013, at the above addressed jobsite, electrical  receptacle outlets used to power tools and other equipment did not have ground fault circuit interrupters installed.  Employees were thereby exposed to electrical shock and electrocution hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1848
  • · Z (S) $3080

1926.404 F06

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 1, 2013
Abate by
Aug 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous:  a) On or about June 19, 2013, at the above addressed jobsite, an extension cord used to power tools and equipment was missing a ground pin, thereby exposing employees to electrical shock and electrocution hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.416 E01

Serious Gravity 10 4 instances 6 exposed
Issued
Aug 1, 2013
Abate by
Aug 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) On or about June 19, 2013, at the above addressed jobsite, extension cords used to power tools and equipment had damaged outer sheathing.  Employees were thereby exposed to electrical shock and electrocution hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 1, 2013
Abate by
Aug 13, 2013
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which is 6 feet  or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:   a) On or about June 19, 2013, at the above addressed jobsite, employees installing plywood on a steel deck roof were not protected from falling approximately 16.5 feet to the concrete floor below.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $1848
  • · Z (S) $3080

1926.760 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 1, 2013
Abate by
Aug 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems:  a) On or about June 19, 2013, at the above addressed jobsite, employees welding steel beams in to place were not protected from falling approximately 19.5 feet to the concrete floor below.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 B02

Repeat Gravity 1 2 instances 6 exposed
Issued
Aug 1, 2013
Abate by
Aug 13, 2013
Penalty
Initial $2,640 · Current $1,584 Reduced
29 CFR 1926.405(b)(2): Outlet boxes were not provided with covers, faceplates, or fixture canopies.   a) On or about June 19, 2013, at the above addressed jobsite, electrical receptacle outlet boxes did not have covers installed, thereby exposing employees to electrical shock hazards.  EMC, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.405(b)(2) which was contained in OSHA inspection number 313931578, citation 1, item number 1, issued on January 13, 2010, and was affirmed as a final order on or about January 19, 2010, with respect to a workplace located at 155 W. Kinzie, Chicago, Illinois.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (R) $1584
  • · Z (R) $2640

View EMC, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339126203.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.