Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: NEMA ENCLOSURES MANUFACTURING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEMA ENCLOSURES MANUFACTURING LLC in 1118 PLEASANTVILLE DR., HOUSTON, TX 77029 (NAICS 332999). OSHA activity number 339126765.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nema Enclosures Manufacturing LLC for free Get an email when a new federal OSHA severe-injury report for Nema Enclosures Manufacturing LLC is published. One employer, no account, unsubscribe in one click.
Site address
1118 PLEASANTVILLE DR.
City
HOUSTON
State
TX
ZIP
77029
Mailing
P.O. BOX 15669, HOUSTON, TX 77220
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
60
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 8 instances 10 exposed
Issued
Jul 8, 2013
Abate by
Aug 26, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    The employer does not develop, document and utilize procedures for the control of potentially hazardous energy to protect employees from injury.       a. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a Streamline waterjet cutter, Model# SL-V 60 Plus, S/N 0602064 without written procedures for the control of the release of potentially hazardous 440VAC electrical, pneumatic and thermal energy.       b. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a Adira Shear, Model# GHS-630, S/N 4116/1076D without written procedures for the control of the release of potentially hazardous 440VAC electrical and hydraulic energy.    c. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a Adira Press Brake, Model# QHD 13540, S/N 5727/10642 without written procedures for the control of the release of potentially hazardous 440VAC electrical and hydraulic energy.      d. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a Adira Press Brake, Model# QHD 5020, S/N 5630/10543 without written procedures for the control of the release of potentially hazardous 440VAC electrical and hydraulic energy.      e. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a Adira Press Brake, Model# QHD 11030, S/N 7019/12075 without written procedures for the control of the release of potentially hazardous 440VAC electrical and hydraulic energy.          f. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a RoboVent Plasma Laser, Model# PAL-25M-5000-4, S/N 22054 without written procedures for the control of the release of potentially hazardous 480VAC electrical and pneumatic energy.      g. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on a Champion Air Compressor, S/N D081351 without written procedures for the control of the release of potentially hazardous electrical and pneumatic energy.       h. This violation occurred on or about June 18, 2013, in the production area where employees were exposed to electrical, caught-in, and struck-by hazards when performing set-up and service on an Ingersol-Rand Air Compressor without written procedures for the control of the release of potentially hazardous electrical and pneumatic energy.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that procedures are developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in activities covered by this standard.
Recent events (2)
  • · I (S) $2100
  • · Z (S) $3500

1910.212 A03 II

Serious Gravity 10 7 instances 11 exposed
Issued
Jul 8, 2013
Abate by
Aug 26, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    The employer does not guard the point of operation of machinery whose operation exposes employees to injury.     a. This violation occurred on or about June 18, 2013, in the center of the facility where an employee was exposed to a stuck-by hazard when operating an Adira shear, Model #GHS-630, S/N 4116/1076D, without a point of operation guard.    b. This violation occurred on or about June 18, 2013, in the rear of the facility where an employee was exposed to a stuck-by hazard when operating a Pemserter , Model #2000, without a point of operation guard.    c. This violation occurred on or about June 18, 2013, in the rear of the facility where an employee was exposed to a stuck-by hazard when operating a Strippit Punch, Model #Super 30-40HD, without a point of operation guard.    d. This violation occurred on or about June 18, 2013, in the rear of the facility where an employee was exposed to a stuck-by hazard when operating an Adira press brake, Model #GHD-13540, S/N 5727/10642, without a point of operation guard.    e. This violation occurred on or about June 18, 2013, in the rear of the facility where an employee was exposed to a stuck-by hazard when operating an Adira press brake, Model #GHD-5020, S/N 5630/10453, without a point of operation guard.    f. This violation occurred on or about June 18, 2013, in the rear of the facility where an employee was exposed to a stuck-by hazard when operating an Adira press brake, Model #GHD-11030PLS, S/N 7019/12075, without a point of operation guard.    g. This violation occurred on or about June 18, 2013, in the center of the facility where an employee was exposed to a struck-by hazard when operating a Kalamazoo band saw, Model #H9AW, without a point of operation guard.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that guards are installed on all machines to protect employees from the point of operation.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.305 B01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 8, 2013
Abate by
Aug 26, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    The employer does not effectively close unused openings on electrical boxes that can expose employees to injury. This violation was observed on or about June 18, 2013, in the center of the facility where employees were exposed to a 440VAC electrical shock hazard when working around a junction box with a knockout opening that was not effectively closed.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that unused openings in boxes, cabinets, or fittings are effectively closed.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.305 B02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 8, 2013
Abate by
Jul 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    The employer does provide covers for electrical junction boxes. This violation was observed on or about June 18, 2013, in the rear of the facility where employees were exposed to a 250 VAC electrical shock hazard when operating a Boshert Lite hydraulic notcher without a cover on the energized wiring.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that covers are provided for all electrical pull boxes, junction boxes and fittings.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Nema Enclosures Manufacturing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339126765.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.