Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TEN HOEVE BROTHERS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TEN HOEVE BROTHERS LLC in 25 POWERS DRIVE, MERIDEN, CT 06451 (NAICS 332313). OSHA activity number 339127185.

Watch TEN Hoeve Brothers LLC — free Get an email when a new federal OSHA severe-injury report for TEN Hoeve Brothers LLC is published. One employer, no account, unsubscribe in one click.
Site address
25 POWERS DRIVE
City
MERIDEN
State
CT
ZIP
06451
Mailing
190 COLONY STREET, MERIDEN, CT 06451
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
9
Ownership type
A

12 citations on file for this inspection.

1910.107 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.107(b)(1): Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.  Location: 25 Powers Drive, Meriden, CT 06451  The lower portion, two to three feet, of the employer's approximately 10 foot wide, 18 foot long and 10 foot high spray booth was constructed of particle board.
Recent events (1)
  • — Z (S) $2000

1910.107 B05 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers.  Location: 25 Powers Drive, Meriden, CT 06451  The approximately 10 foot wide, 18 foot long and 10 foot high spray booth was not protected with an automated sprinkler system.
Recent events (1)
  • — Z (S) $0

1910.107 F04

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1910.107(f)(4): An adequate supply of suitable portable fire extinguishers were not installed near all spraying areas.  Location: 25 Powers Drive, Meriden, CT 06451  The employer did not maintain an adequate supply of fire extinguishers near the approximately 10 foot wide, 18 foot long, and 10 foot high spray booth.
Recent events (1)
  • — Z (S) $1200

1910.132 D02

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed.  Location: 25 Powers Drive, Meriden, CT 06451  The employer did not verify, through a written hazard assessment, that the workplace was evaluated for the proper use and wearing of personnal protective equipment by the employees.
Recent events (1)
  • — Z (S) $1200

1910.178 L01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  Location: 25 Powers Drive, Meriden, CT 06451  The employer did not ensure, by performing formal training and operator evaluation, that the employee who was assirgned to operate the powered industrial truck was competent.
Recent events (1)
  • — Z (S) $1600

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  Location: 25 Powers Drive, Meriden, CT 06451  The compressed oxygen cylinders were stored next to fuel gas (P-75) compressed gas cylinders along the west wall.
Recent events (1)
  • — Z (S) $1600

1910.305 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front.  Location: 25 Powers Drive, Meriden, CT 06451   The paneboard mounted on the east wall did not contain a dead front to enclosed the energized electrical wires.
Recent events (1)
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  Location: 25 Powers Drive, Meriden, CT 06451  A written hazard communication program was not developed and implemented that describes how the specific program elements of this standard will be accomplished/completed.
Recent events (1)
  • — Z (S) $1600

1910.1200 G01

Serious Gravity 5 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use.  Location: 25 Powers Drive, Meriden, CT 06451   Material safety data sheets (MSDSs) for each hazardous material and/or solvent were not readily available for their employees to use and reference as needed.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1):  Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area.  Location: 25 Powers Drive, Meriden, CT 06451  Training and information was not conducted with employees working with hazardous materials and substances at the time of their initial assignment and whenever a new hazard was introduced into the workplace.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit".   Location: 25 Powers Drive, Meriden, CT 06451   The designated exit door on the east side of the building was not properly labeled with an "Exit" sign.
Recent events (1)
  • — Z (O) $0

1910.37 B05

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet).  Location: 25 Powers Drive Meriden, CT. 06451  A door located on the east wall of the building was not marked with a "Not an Exit" or similar designation.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339127185.