PLANT CITY, FL ·
OSHA Inspection: H.D. BUDD FARMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of H.D. BUDD FARMS, INC. in 3701 E TRAPPNELL RD, PLANT CITY, FL 33566 (NAICS 111219). OSHA activity number 339127342.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H.D. BUDD FARMS, INC.
- Site address
- 3701 E TRAPPNELL RD
- City
- PLANT CITY
- State
- FL
- ZIP
- 33566
- Mailing
- 3701 E TRAPPNELL RD, PLANT CITY, FL 33566
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 111219
- Employees
- 40
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.23 D01
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Flights of stairs having four or more risers were not equipped with a standard railing as specified in paragraphs (d)(1)(i) through (v) of this section: a) Open Bay Parking Area - Near Office Stairwell missing a midrail, on or about, 07/31/13. b) Open Bay Parking Area - Near Repack Line Stairwell missing a top rail and a midrail, on or about, 07/31/13. c) West Entrance - Employee Parking Area - Stairwell missing midrails, on or about, 07/31/13. d) Storage Area - Stairwll missing a top rail and a conmidrail, on or about, 07/31/13.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.132 A
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) Mezzanine - Boxloft - Loading/Unloading Gate Area Personal protective equipment was not provided when opening and closing the mezzanine gate exposing the employee to a 12-foot fall to the floor, as observed on or about 08/07/13. Exposure occurs prior to receipt of pallets containing unmade boxes and after the last pallet containing newly constructed boxes is lowered to the floor below.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.147 C01
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) For equipment throughout the plant, such as but not limited to: the conveyor belt system, the harvester machine, and the radius link belt. The employer did not establish and implement a written Energy Control Program, on or about 08/07/13.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.151 C
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) at the Wash Area repack line where employees empty chlorine bottles once per day. An eyewash facility was not provided, as observed on or about 07/31/13.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.219 C04 I
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) for the shaft ends shaft ends at the Head End of the Repack Belt, as observed on or about 08/07/13. The shaft ends were unguarded and projected more than one half the diameter of the shaft.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.304 G05
- Issued
- Aug 21, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) in the Repack Conveyor Belt Area: the Maxx Air High Velocity Fan was missing the ground from plug connection, as observed on or about 07/31/13.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.1200 E01
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Throughout Plant The employer had not developed or implemented a written Hazard Communication program despite the presence and use of such hazardous material including but not limited to Propane, Chlorine, Ethy-Gen II, etc; on or about, 08/07/13.
Recent events (2)
- · I (S) $1260
- · Z (S) $2100
1910.303 B01
- Issued
- Aug 21, 2013
- Abate by
- Oct 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Repack Conveyor Line - Fluorescent light - Ceiling Area - Second light on left & right banks - Outer insulation fraid and torn on light's power cords allowing for exposed insulated inner conductors, on or about, 08/07/13.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 111219)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339127342.