MEXICO, MO —
OSHA Inspection: MEXICO HEATING CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MEXICO HEATING CO., INC. in 21450 HWY FF, MEXICO, MO 65265 (NAICS 332322). OSHA activity number 339128001.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEXICO HEATING CO., INC.
- Site address
- 21450 HWY FF
- City
- MEXICO
- State
- MO
- ZIP
- 65265
- Mailing
- P.O. BOX 189, MEXICO, MO 65265
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.215 A04
- Issued
- Jul 17, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $990 · Current $693 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest to support offhand grinding work: At the time of the inspection, the Baldor pedestal grinder was used to sharpen mower blades without using a work rest. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations
Recent events (2)
- — I (S) $693
- — Z (S) $990
1910.219 C04 II
- Issued
- Jul 17, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $990 · Current $693 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: At the time of the inspection, on the coil line a shaft with an exposed keyway was not covered or otherwise protected. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations
Recent events (2)
- — I (S) $693
- — Z (S) $990
1910.22 D01
- Issued
- Jul 17, 2013
- Abate by
- Aug 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. At the time of the inspection, several mezzanine areas where employees occupied space below them were not marked with the approved weight limits for storage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mexico Heating CO., INC.
View Mexico Heating CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339128001.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.