Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: AZAD CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AZAD CONSTRUCTION, INC. in 1029 E. 230TH STREET, BRONX, NY 10466 (NAICS 238140). OSHA activity number 339128084.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Azad Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Azad Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1029 E. 230TH STREET
City
BRONX
State
NY
ZIP
10466
Mailing
1673 E. GUNHILL RD, BRONX, NY 10469
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
Private (A)

9 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:  On or about 6/17/2013, 1029 E. 230th Street  a) The employee was using a chipping hammer and grinder to remove concrete. He was not wearing eye/face protection.
Recent events (1)
  • · Z (S) $1200

1926.300 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use:  On or about 6/17/2013, E. 230th Street  a) The Craftsman 7 1/4" grinder, used by employees, was not equipped with a guard.
Recent events (1)
  • · Z (S) $1200

1926.405 A02 II I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage:  On or about 6/17/2013, 1029 E. 230th Street  a) The door was closed over on the extension cord causing a pinch point.
Recent events (1)
  • · Z (S) $1200

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:  On or about 6/17/2013, E. 230th Street  a) Employees worked from a tubular welded frame scaffold that was not fully planked.
Recent events (1)
  • · Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access:  On or about 6/17/2013, E. 230th Street  a) The employee climbed on the scaffold frame to gain access to and from the work platform.
Recent events (1)
  • · Z (S) $1600

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:                       *Insulated Lines  _____________________________________________________________________                                                    Voltage          Minimum distance           Alternatives ____________________ ________________________ _______________________                                               Less than 300 volts.  3 feet (0.9 m)           300 volts to 50 kv.  10 feet (3.1 m)          More than 50 kv.....  10 feet (3.1 m) plus     2 times the length                       0.4 inches (1.0 cm)      of the line                       for each 1 kv over       insulator, but never                       50 kv.                   less than 10                                                feet (3.1 m). ____________________ ________________________ _______________________                         *Uninsulated lines _____________________________________________________________________                                                   Voltage           Minimum distance         Alternatives ____________________ ________________________ _______________________                                               Less than 50 kv.....  10 feet (3.1 m).         More than 50 kv.....  10 feet (3.1 m) plus     2 times the length of                       0.4 inches (1.0 cm)      the line insulator,                       for each 1 kv over       but never less than                       50 kv.                   10 feet (3.1 m). ____________________ ________________________ _______________________  Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines:   On or about 6/17/2013, E. 230th Street  a) The employee was removing concrete and within 2' of the main electrical service panel.
Recent events (1)
  • · Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers:  Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.  On or about 6/17/2013, E. 230th Street  a) The tubular welded frame scaffold did not have guardrails. The employee was exposed to a 24' fall hazard.
Recent events (1)
  • · Z (S) $2800

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  ON or about 6/17/2013, E. 230th Street  a) The 19' aluminum ladder had a bracket and a 2x10 wood plank. The employee was not protected from falling off the platform.
Recent events (1)
  • · Z (S) $0

1926.454 A

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:  On or about 6/17/2013, E. 230th Street  a) The employee was not trained as required by the standard.
Recent events (1)
  • · Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339128084.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.