OSHA Inspection: RUBAL CONSTRUCTION CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RUBAL CONSTRUCTION CORP. in 2705 EASTCHESTER RD, BRONX, NY 10469 (NAICS 238140). OSHA activity number 339128423.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rubal Construction Corp. for free Get an email when a new federal OSHA severe-injury report for Rubal Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
2705 EASTCHESTER RD
City
BRONX
State
NY
ZIP
10469
Mailing
35-37 90TH STREET, JACKSON HEIGHTS, NY 11372
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors:    On or about 6/19/2013, Eastchester Rd.    a) The employees were using grinders to remove concrete. The tools were energized through two extension cords without ground fault circuit interrupters.
Recent events (3)
  • · F (S) $800
  • · C (S) $1600
  • · Z (S) $1600

1926.405 A02 II I

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 27, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage:    On or about 6/19/2013, Eastchester Rd.    a) The two extension cords powering equipment used by employees were caught in the doorway causing a pinch point.
Recent events (3)
  • · F (S) $800
  • · C (S) $1600
  • · Z (S) $1600

1926.451 G01 II

Serious Gravity 10 2 instances 2 exposed
Issued
Jun 27, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold shall be protected by both a personal fall arrest system and guardrail system:    On or about 6/19/2013, Eastchester Rd.    a) The employees were working from a two point suspension scaffold. They were not protected from a fall hazard.
Recent events (3)
  • · F (S) $1400
  • · C (S) $2800
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 27, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support:    On or about 06/19/2013, Eastchester Rd.    a) The 30' aluminum extension ladder used by employees was not secured to prevent displacement.
Recent events (3)
  • · F (S) $1000
  • · C (S) $2000
  • · Z (S) $2000

1926.1053 B12

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 27, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(12): Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in 1926.951(c)(1) of this part:    On or about 6/19/2013, Eastchester Rd.    a) The 30' aluminum extension ladder used by employees was within 2' of the main electrical service panel.
Recent events (3)
  • · F (S) $1000
  • · C (S) $2000
  • · Z (S) $2000