OSHKOSH, WI ·
OSHA Inspection: OSHKOSH DEFENSE - SOUTH PLANT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OSHKOSH DEFENSE - SOUTH PLANT in 333 W 29TH AVENUE, OSHKOSH, WI 54902 (NAICS 336992). OSHA activity number 339129280.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSHKOSH DEFENSE - SOUTH PLANT
- Site address
- 333 W 29TH AVENUE
- City
- OSHKOSH
- State
- WI
- ZIP
- 54902
- Mailing
- P.O. BOX 2566, OSHKOSH, WI 54902
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336992
- Employees
- 684
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.178 N06
- Issued
- Jul 11, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.178(n)(6): Industrial truck drivers were not required to look in the direction of, and keep a clear view of the path of travel: a) On 6/25/13, a lift truck operator was moving a large van body into station #37 when he could not see in front of the load. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- · F (S) $2500
- · C (S) $5000
- · Z (S) $5000
1910.184 H05 III
- Issued
- Jul 11, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.184(h)(5)(iii): Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service: a) At rework station 12 1/2, the nylon sling had a cut in it and a red thread showing. NO ABATEMENT CERTIFCATION REQUIRED
Recent events (3)
- · F (S) $0
- · C (S) $4000
- · Z (S) $4000
1910.184 I01
- Issued
- Jul 11, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $0 · Current $2,000
General-duty citation text
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: a) At the T case S430 work station, a nylon sling did not have a legible label. b) At the Cab CMM area, a nylon sling did not have a load rating tag. NO ABATEMENT CERTIFCATION REQUIRED
Recent events (3)
- · F (O) $2000
- · C (S) $0
- · Z (S) $0
1910.242 B
- Issued
- Jul 11, 2013
- Abate by
- Jul 23, 2013
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) At the station 104 Chassis line, an air hose was used with wand end that did not reduce air to to less than 30 p.s.i. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- · F (S) $0
- · C (S) $3000
- · Z (S) $3000
1910.1200 F05 I
- Issued
- Jul 11, 2013
- Abate by
- Jul 23, 2013
- Penalty
- Initial $500 · Current $500
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) One gallon paint can on cart in commercial cab area by door #8810 was labeled WASH GAS and contained HYDRITE BLEND 4567. Procedural sheet at 55 gallon drum safety cabinet transfer station was labeled WASH GAS and the label at #1 IDS axle carrier 3811 work station for the safety pump can location was labeled WASH GAS. Oshkosh Defense was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(i) which was contained in OSHA inspection number 312559081, citation number 02, item number 001(a) and was affirmed as a final order on 1/31/2011, with respect to a workplace located at 333 West 29th Avenue, Oshkosh, WI 54902. Oshkosh Defense was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(i) which was contained in OSHA inspection number 312554314, citation number 01, item number 001 and was affirmed as a final order on 2/3/2010, with respect to a workplace located at 2737 Harrison Street, Oshkosh, WI. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- · F (O) $500
- · C (R) $500
- · Z (R) $500
1910.1200 F05 II
- Issued
- Jul 11, 2013
- Abate by
- Jul 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) Mouse trap access area, ST. 46 Antifreeze labeled tank without a hazard warning label. b) Mouse trap access area, ST. 46 Diesel Fuel labeled tank without a hazard warning label. Oshkosh Defense was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(ii) which was contained in OSHA inspection number 312559081, citation number 02, item number 001(b) and was affirmed as a final order on 1/31/2011, with respect to a workplace located at 333 West 29th Avenue, Oshkosh, WI 54902. Oshkosh Defense was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(5)(ii) which was contained in OSHA inspection number 312554314, citation number 01, item number 001 and was affirmed as a final order on 2/3/2010, with respect to a workplace located at 2737 Harrison Street, Oshkosh, WI. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- · F (R) $0
- · C (R) $0
- · Z (R) $0
1910.244 A02 VI A
- Issued
- Jul 11, 2013
- Abate by
- Aug 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(2)(vi)(a): Each jack used constantly or intermittently at a single locality was not thoroughly inspected at least once every six months: a) In Bay #3 in the PDI area a GRAY FSJ 200 floor jack was not receiving preventive maintenance inspections. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
1910.305 G02 III
- Issued
- Jul 11, 2013
- Abate by
- Jul 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) In Bay #1 in the PDI area, a movable 2 ton hoist had electrical wires pulled from the electrical box. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0