Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: US ERECTORS, INC.

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of US ERECTORS, INC. in 3600 30TH STREET, DES MOINES, IA 50310 (NAICS 238120). OSHA activity number 339129488.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for US Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
US ERECTORS, INC.
Site address
3600 30TH STREET
City
DES MOINES
State
IA
ZIP
50310
Mailing
1226 ILLINOIS STREET, DES MOINES, IA 50314
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
60
Ownership type
A

6 citations on file for this inspection.

1910.1200 E02 I

Serious Gravity 5 1 instance 600 exposed
Issued
Jul 24, 2013
Abate by
Aug 19, 2013
Penalty
Initial $4,200 · Current $4,200

Hazardous substances 0430137125872610

29 CFR 1910.1200(e)(2)(i): At a multi-employer workplace, the employer's hazard communication program did not include methods the employer used to provide other employers with on-site access to a material safety data sheet for each hazardous chemical the other employer(s)' employees may be exposed to while working: (Construction Reference: 1926.59)    (a) At the Dept of Veterans Affairs Central Iowa Veteran Health Care System, US Erectors were welding on galvanized steel and using SprayOn Zinc-Rich Cold Compound. While US Erectors had a written hazard communication program, it did not include the methods used to provide the VA and other contractors access to safety data sheets for each hazardous chemical that VA employees were exposed to.  The hazardous chemicals included but not limited to welding fumes associated with welding on galvanized steel using E7018 welding rods and SprayOn Zinc-Rich Cold Galvanizing Compound.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $4200

1910.1200 E02 II

Serious Gravity 5 1 instance 600 exposed
Issued
Jul 24, 2013
Abate by
Aug 19, 2013
Penalty
Initial $4,200 · Current $0 Reduced

Hazardous substances 0430137125872610

29 CFR 1910.1200(e)(2)(ii): At  a multi-employer workplace, the employer's hazard communication program did not include methods the employer will use to inform the other employer(s) of any precautionary measures that need to be taken to protect employees during the workplace's normal operations and in foreseeable emergencies:    (a) At the Dept of Veterans Affairs Central Iowa Veteran Health Care System, US Erectors were welding on galvanized steel and using SprayOn Zinc-Rich Cold Compound. While US Erectors had a written hazard communication program, it did not include the the methods for informing the VA and other employers of precautionary measures that were needed to protect VA employees from US Erectors work process in Building 3 on the entry stairs project. VA employees were exposed to the welding fumes generated when US Erectors employees welded on galvanized steel using E7018 welding rods.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1910.1200 G08

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2013
Abate by
Aug 19, 2013
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace:  (a)  The US Erectors did not maintain Material Safety Data Sheets for each hazardous material, such as but not limited to, galvanized steel ASTM A36, where their employees were welding the steel in Building 3 entry stairs project, exposing their employees to hazardous materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1910.1200 H03 IV

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2013
Abate by
Aug 19, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.1200(h)(3)(iv): Employee training did not include the details of the hazard communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information: (Construction Reference: 1926.59)  (a) Under the multi-employer worksite policy, US Erectors employees were not trained on the Material Safety Data Sheet for the galvanized steel beams that they were welding on for the Dept of Veterans Affairs stairs project.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.20 B01

Serious Gravity 5 1 instance 600 exposed
Issued
Jul 24, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part.  (a)  US Erectors did not maintain such programs as may be necessary to comply with this part in that US Erectors work process exposed Dept of Veterans Affairs Central Iowa VA Health Care System employees to welding fumes.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3500

1926.353 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.353(b)(2): Employee(s) in a confined space where welding, cutting, or heating was performed and where sufficient ventilation could not be obtained without blocking the means of access, were not protected by air line respirators in accordance with the requirements of Subpart E of this part:  (a) At the Dept of Veterans Affairs Central Iowa Veteran Health Care System where US Erector employees were welding in a confined space, an industrial fan blocked the means of access and air line respirators were not used to protect employees.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3500

View US Erectors, INC.'s full OSHA safety record →