Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STAR PIPE PRODUCTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STAR PIPE PRODUCTS in 4018 WESTHOLLOW PARKWAY, HOUSTON, TX 77082 (NAICS 331210). OSHA activity number 339134025.

Watch Star Pipe Products — free Get an email when a new federal OSHA severe-injury report for Star Pipe Products is published. One employer, no account, unsubscribe in one click.
Establishment
STAR PIPE PRODUCTS
Site address
4018 WESTHOLLOW PARKWAY
City
HOUSTON
State
TX
ZIP
77082
Mailing
4018 WESTHOLLOW PARKWAY, HOUSTON, TX 77082
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
120
Ownership type
A

3 citations on file for this inspection.

1910.157 C01

Other-than-serious 4 instances 10 exposed
Issued
Penalty
Initial $2700.00 · Current $2700.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:        In the warehouse, fire extinguishers are not mounted or readily available, exposing employees to potential fire hazards.
Recent events (2)
  • — I (O) $2700
  • — Z (S) $2700

1910.176 B

Serious Gravity 5 10 instances 10 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2250.00 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:         In the warehouse area adjacent to the loading dock, materials were not properly stored, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

1910.305 B01 I

Other-than-serious 3 instances 10 exposed
Issued
Penalty
Initial $2700.00 · Current $2700.00
29 CFR 1910.305(b) (1) (i): Conductors entering cutout boxes, cabinets, or fittings was not protected from abrasion, and openings through which conductors enter were not effectively closed.          At the loading dock area, electrical control boxes were not protected from abrasion and unused opening were not effectively closed, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $2700
  • — Z (S) $2700

View STAR PIPE PRODUCTS's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339134025.