Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: MALECKI CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MALECKI CONSTRUCTION in 518 TREMONT STREET, BOSTON, MA 02121 (NAICS 238350). OSHA activity number 339138307.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Malecki Construction for free Get an email when a new federal OSHA severe-injury report for Malecki Construction is published. One employer, no account, unsubscribe in one click.
Site address
518 TREMONT STREET
City
BOSTON
State
MA
ZIP
02121
Mailing
500 BARRE ROAD, TEMPLETON, MA 01468
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.502 A02

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 8, 2013
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection.    Jobsite:    Employees did not have fall protection system in place where the temporary handrails / midrails were removed that morning.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $2800

1926.502 B02 I

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Aug 8, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.502(b)(2)(i): Midrails, when used, shall be installed at a height midway between the top edge of the guardrail system and the walking/working level.  Jobsite:  Employees removed temporary mid-rails and toe boards from second story floor exposing employees to falling material and from falling out of the open window.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339138307.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.